41S_Rev00
16
Basic Operation
Power Supply
This section describes the procedures for using the power supply with the equipment.
Splicer is operated with AC adapter (ADC-19A) or the internal battery. Use the only
external AC adapter (ADC-19A) and AC Coad (ACC-**) with Splicer.
AC Operation
Insert AC cord into the AC inlet of the AC adapter. The power ON LED of the AC adapter
changes green color when suitable AC voltage is supplied.
If high AC Voltage is supplied, the AC adapter will immediately be damaged.
AC generators commonly produce abnormally high AC output voltage.
Measure the output AC voltage with a circuit tester before connecting the AC power
cord. Such abnormally high voltage or frequency from a generator may cause fuming,
electric shock or equipment damage and may result in personal injury, death or fire.
Notes: when using an AC adaptor BTR-11
If AC adaptor is used without battery pack BTR-11, some error may be occur. Please
operate the splicer with battery pack BTR-11
AC Adapter [ADC-19A]
AC Coad [ACC-**]
Inlet
ADC-19A
Insert