62S_Rev3
20
Basic Operation
Battery Operation
Check the remaining battery capacity. If it is 20% or less before operation, splicer can only
work a few times.
How to check remaining battery capacity
If splicer is already equipped with the battery, turn splicer ON. Power source of "Battery"
is automatically identified and the remaining battery capacity is displayed on the
"READY" screen.
Remaining battery capacity display
Remaining battery
(
95~100%
(
65~95%
(
40~65%
15~40%
Flashing
Less than 15%
READY screen
Keep below practices to prevent battery damage.
The capacity of the battery gradually decreases as nature even if it is not used. If the
battery discharges completely, the battery may no longer be able to be re-charged.
Charge the battery before long time storage and after every use.
If a battery is to be stored for a long time, periodical charge of every six months is
recommended regardless of battery charge level of the battery.
Follow below conditions
Operation
: -10 degree C ~ 50 degree C
Charging
: 0 degree C ~ 40 degree C
Storage
: -20 degree C ~ 30 degree C