62S_Rev3
61
Splice Menu
Manual Splice Mode
This mode is to manually align and splice fibers. The following procedure is required, and is
different from standard automatic splicing.
1.
Select a splice mode that allows the splice parameter [Align] in page two of splice mode
edit menu to be changed to “manual” (i.e. SM-SM mode).
2.
Press SET key to drive the fibers forward. The fibers stop moving forward at the Gapset
position.
3.
Select a motor to be manually moved by pressing MENU key. The name of the motor to
be moved is displayed in the monitor. Motor speed can be selected "fast" or "slow" by
pressing SET key.
4.
Press Up/Down Arrow key to move the selected motor and drive the fibers forward or
backward.
5.
After manual alignment is completed, press ARC key to arc and splice the fibers.
Motor
Up Arrow key
Down Arrow key
ZL/ZR
Forward
Backward
X/Y
Upward
Downward
Focus X/Y Lens moves nearer fiber.
Lens moves away from fiber.
The splicer beeps if motor reaches its limit and stops. Press the opposite arrow key
to move the motor again.
Display messages can be erased by pressing ENT key. The message can be
displayed by pressing ENT key again.