Maintenance
Dust Check
The splicer observes fibers through image processing. Dust or contaminants on the cameras
and lenses disturb normal observation of fibers and may result in improper splicing. This
function checks the optical path for the presence or absence of contaminants and judges
whether they cause trouble for fiber splicing.
Operation Procedure
1.
Select the [Dust Check] in the [Maintenance
Menu].
2.
If fibers are set in the splicer, remove them
and press ENT key again. The splicer begins
the dust check.
3.
After observation, the location of
contamination judged as a potential problem
blinks. If contamination is discovered, clean
the objective lenses and redo [Dust Check] for
cleaning instructions.
4.
Press ESC key to finish dust check.
In case you have cleaned the objective lenses and dirt or dust still remains, contact
the authorized distributor.