Stripper Setting
This function selects the unit to change the parameters of the RS02/03.
When selecting “Splice Mode”, the RS02/03 heats the fiber with the splicer parameters set in
[Splice Mode]. In this case, the all buttons except for the power button on the RS02/03 are
disabled.
When selecting “Stripper”, the RS02/03 heats the fiber with using the parameters set in the
memory inside the RS02/03. In this case, the operator changes the settings of the RS02/03 with
the RS02/03 buttons.
Parameter
Description
Heat Settings
Heat Parameter Control
Selects the unit for heater parameter control.
Heat Temperature Level
Sets the heater temperature level of the stripper.
Heat Finish Time
Sets the heating time of the stripper.
ECO Setting
ECO Mode Control By
Selects the unit for the ECO mode control.
ECO Mode
Toggles ECO mode ON/OFF.
Temperature Keeping
Sets the time delay before ECO mode initiates.
Buzzer Settings
Buzzer Volume
Sets buzzer volume and under what conditions it is activated.
Power On
(Only RS03)
Power Off
(Only RS03)
Heat Finish
Auto Shut Down
(Only RS03)
End of Charging