70S+A_Rev1
106
Error Message List
Error
Message
Reason
Solution
ZL Motor
Overrun
(Forward)
・
The fiber is not set
correctly at the bottom of
the V-groove. The fiber
is not located in the
Camera’s field of view.
・
The cleave length (bare
fiber part) is too short.
・
Press RESET key, and set the fiber again to
seat it correctly at the bottom of the V-groove.
・
Confirm the setting position of the stripped fiber
end on the fiber cleaver. Check the cleave
length.
ZR Motor
Overrun
(Forward)
ZL Motor
Overrun
(Backward)
・
The taper speed or taper
time is set too high.
・
Adjust the taper parameters in the splice mode.
ZR Motor
Overrun
(Backward)
・
Only occurs in manual motor operation.
X motor
Overrun
・
The fiber is not set
correctly at the bottom of
the V-groove. The fiber
is offset too far and it
exceeds the X or Y motor
range.
・
Press RESET key and re-position the fiber
again to seat it correctly at the bottom of the
V-groove.
Y Motor
Overrun
Focus X
Motor
Overrun
・
The fiber is not set
correctly at the bottom of
the V-groove. The fiber
position is out of focus
range.
・
Dust or dirt is on the fiber
surface resulting in focus
failure.
・
Dust or dirt is on the
objective lens.
・
Press RESET key, and re-position the fiber
again to seat it correctly at the bottom of the
V-groove
・
Completely prepare the fiber again (strip, clean
and cleave).
・
Execute the [Dust Check]. Clean the lens.
Focus Y
Motor
Overrun
Cover
Opened
・
The wind-protector is
opened during splicing
operation.
・
Press RESET key after closing the
wind-protector.
ZL/R
X/Y
Focus X/Y
Cover F/R
Heater
Motor trouble
・
Motor might be
damaged.
・
Consult the authorized distributor.