70S+A_Rev1
113
Questions and Troubleshooting
(10)
Method to display Cleave Angle, Fiber Angle / Offsets
・
See Section [Splice Menu]. The fiber angle is not displayable in the SM, DS, MM or AUTO
mode.
(11)
Incorrect splice mode selected and used in AUTO mode
・
The AUTO mode can detect only standard SM, DS, MM and NZDS fibers. When splicing
specialty fibers, the AUTO mode may identify them incorrectly.
Tube-heating Operation
(1)
Fiber protection sleeve does not shrink completely
・
Fiber protection sleeve might not be set to the tube heater properly.
・
When setting the fiber to the heater, do not remove hands from the fiber until the heater
cover closes and the buzzer sounds. If releasing hands from the fiber rapidly, the
protection sleeve may not be set to the heatable position.
・
If the protection sleeve is not centered between yellow lines, the protection sleeve might
not shrink completely.
・
Extend the heating time.
・
Refer to [Heater Mode].
(2)
Heater LED on panel keyboard blinks
・
Pressing the HEAT key during heating causes the LED to blink. The tube heater is turned
off if the HEAT key is pressed again. If, after 2 seconds have gone by without pressing the
HEAT key again, the LED stays on continuously and the heater returns to its normal state.
The LED will turn off when the heat cycle is completed.
・
If the heating temperature does not reach its inputted setting, the LED blinks and the alarm
sounds. If this happens, contact the authorized distributor.
(3)
Fiber protection sleeve adhered to heating plate after shrink
・
Use a cotton swab or a similar soft tip object to push and remove the sleeve. If the black
coating is removed, contact your authorized distributor.
(4)
Method to initialize heating condition of Heater mode
・
See Section [Referring to or editing Heater Mode].
(5)
Method to cancel heating process
・
RESET key does not cancel the heater. Press HEAT key twice to cancel the heating
process.