70S+A_Rev1
47
Basic Operation
6. Optical fiber is conveyed to a heater unit, and it takes down to a heater part and holds.
If a protection sleeve is not centered between yellow lines, the protection sleeve may not
shrink completely. In this case, please set to a heater once again and perform
re-heating.
7. Heater lid automatically closes when fiber is set. Do not remove hands from fiber until
heater holds the fiber.
8. If heat processing is completed, buzzer will sound and a heater lid will open automatically.
Visually inspect the finished sleeve to verify no bubbles or debris/dust is present in
the sleeve.
If HEAT key is pressed during tube heating, the HEAT LED blinks. If HEAT key is
pressed again, the tube heating process is aborted.
Protection sleeve may stick to heater plate surface. Use a cotton swab to remove
sleeve from heater.
Since it gets very hot in the heater and the sleeve will get hot, you should not touch
the sleeve immediately after heating.
Make sure the splice point is located at the center of the protection sleeve.
Notes at the time of a sleeve set!!
Apply tension to the fiber until
heater holds the fiber.
If a hand is lifted immediately,
it will be installed in at the
bottom, without being held at
the heater, and will not be in
contact.
Apply tension to the
fiber until heater holds
the fiber.