70S+A_Rev1
77
Heater Menu
The dimensions of the Protection Sleeve after heat shrink
Form
Tension member
Sleeve
length
Prepare fiber
length
Diameter of
an adaptation
optical fiber
Diameter
of a result
FP-03
SUS
60mm
16mm or less 250~900um
3.1mm
FP-03(40mm)
SUS
40mm
10mm or less 250~900um
3.1mm
FP-04T
Glass ceramic
40mm
10mm or less 250~900um
4.0mm
FPS01-400-15 SUS
15mm
5mm or less
~400um
1.5mm
FPS01-900-20 SUS
20mm
6mm or less
~900um
2.3mm
* The dimensions of the protection sleeve after shrink vary depending on the
diameter of the fiber.
Selecting Heater mode
How to check the current heater mode
1. The current heater mode is displayed on the OK screen.
Sleeve length *
Outer tube
Inner tube
Tension member
When using a protection sleeve which is not made by Fujikura, please set
parameters based on the specific sleeve.
When the sleeve of another company is used, the durability of a protection point