70S+A_Rev1
85
Maintenance
Motor Drive
Some motors in a splicer can carry out manual operation separately. In the course of splicing,
the motors can also be operated by calling this menu in the [PAUSE], or [FINISH] state.
1. Select the [Motor Drive].
2. Pressing MENU key changes motor selection. The name of the selected motor is
displayed in the upper section of the screen.
3. Press Up/Down Arrow key to drive the motor in the desired direction.
Motor
Up Arrow key
Down Arrow key
ZL/ZR
Forward
Backward
X/Y
Upward.
Downward.
Focus X/Y
Lens moves
nearer fiber.
Lens moves away
from fiber.
Cover F/R
Open the Wind
Protector.
Close the Wind
Protector.
When the motor reaches the limit of the operating range, the buzzer sounds and the
motor stops. Press the opposite arrow key to reverse and move the motor again.
Display messages can be erased by pressing ENT key. The message can be
displayed by pressing ENT key again.
If the motor is moved too much with respect to the spliced fiber, the fiber may break.