70S+A_Rev1
92
Maintenance
A continuation of
edit parameter list
Parameter
Description
Power Saving Timer
Sleep(Battery)
Setting Sleep function turns off the power supply to the LCD
Monitor if the splicer performs no operation after a certain period of
time. When power-saving mode starts and the LCD monitor's power
supply is turned off, LED of the SET key side blinks.
When returning from a sleep state, it returns by pressing keys other
than HEAT key. Automatically turns off the power supply to the splicer if
it performs no operation for a certain period of time. The function
serves to prevent the battery capacity from running low if the splicer is
left on for an extended period of time.
Shut Down(Battery)
Sleep(AC)
Shut Down(AC)
Power On Option
Opening Title 1
Sets the message to be displayed when the splicer power is turned on.
Max number of characters: 15
Opening Title 2
Electrode
Electrode Caution
When the number of splices exceeds the selected [Electrode Caution]
value, the caution message prompting the operator to replace the
electrodes is displayed when the splicer power is turned on.
When the number of splices exceeds the selected [Electrode Warning]
value, the caution message changes to the warning message.
Electrode Warning
Alarm Display during
Reset
ON/OFF setup of displaying the above message when the splicer
return to the ready state.
Cleaver Blade Alarm
Blade Position
Change
ON/OFF setup of the warning of the Cleaver counter can be performed.
In OFF, warning is not indicated on a screen.
Blade Height
Change
Blade Replacement
Arc Calibration
Cleave Limit
Sets the threshold of the cleave angle error for the [Arc Calibration].
Max Number of
Tests
Enables setting a maximum number of Arc Calibration re-test cycles
after which the [Arc Calibration] process is complete. This may be set to
infinity for operators who need very precise [Arc Calibration].