70S_Rev1
32
Basic Operation
Loading fiber to splicer
Using sheath clamp
1.
Open the wind-protector and sheath clamps.
2.
Place prepared fiber onto v-groove so that the fiber tip is located
between the v-groove edge and tip of electrode.
3.
Hold fiber with fingers and close sheath clamp so that the fiber does not move.
Make sure the fiber is placed in the bottom of the v-grooves. If fiber is not placed
properly, reload fiber.
The prolonged storage back and when splicing for the first time, we recommend
you execute for an Arc Calibration.
Refer to [Arc Calibration].
Be careful not to contact the prepared fiber tips into anything to maintain fiber
end-face quality.
Be careful of a fiber tip to
v-groove and electrode.
Set so that a fiber tip comes to
red frame area.
V-groove
Electrode
Fiber
Electrode