Basic Operation
Fiber Proof Test
The strength of the splice point can be checked. When finished press RESET or open
wind-protector and fiber proof test will be performed.
Heating protection sleeve
1. Hold left fiber with left hand at the edge of splicer.
2. Open the right side sheath clamp lid.
3. Place the protection sleeve over the Right side fiber to splice point.
4. Hold right fiber with right hand, and remove the splicer.
5. If a protection sleeve is put on the centering guide on the heater upper surface
and a left position is moved in the case of the equipment left, a connection point
will be moved focusing on a protection sleeve.
A protection sleeve is moved to a splice point, holding a fiber with the left hand.
It prevents slack from occurring at a splice point.
Moreover, there is a possibility of fracturing if an excessive tension starts.
Keep holding fiber until fiber is completely transferred to tube heater.
Check that the splice point is located in the center of a protection sleeve.
Check whether the twist has occurred on the right-and-left fiber.
A tension member is designed to rest below a splice point.
A motion changes by the