70S_Rev1
42
Basic Operation
6. Optical fiber is conveyed to a heater unit, and it takes down to a heater part and holds.
When a protection sleeve set position exceeds a yellow line, un-contracting of a
protection sleeve occurs.
In this case, please set to a heater once again and perform re-heating.
7. Heater lid automatically closes when fiber is set. Do not remove hands from fiber until
heating starts followed by beeps.
8. If heat processing is completed, buzzer sound will sound and a heater lid will open
automatically.
Visually inspect the finished sleeve to verify no bubbles or debris/dust is present in
the sleeve.
Make sure the splice point is located at the center of the protection sleeve.
Make sure the strength member in the protection sleeve is placed on bottom.
If HEAT key is pressed during tube heating, the HEAT LED blinks. If HEAT key is
pressed again, the tube heating process is aborted.
Protection sleeve may stick to bottom plate of heater. Use a cotton swab to help
remove sleeve from heater.
Since it gets very hot in the heater and the sleeve will get hot, you should not touch
the sleeve immediately after heating.