Parameter
Description
Prefuse And Stuff
Prefuse Power
Sets the power of the prefuse arc, which is an arc discharge occurring from
the beginning until the fibers begin stuffing. If [Prefuse Power] is set too low,
axial offset may occur if cleaved angles are relatively poor. If [Prefuse Power]
is set too high, fiber end faces are fused excessively and splice loss gets
worse.
Prefuse Time
Sets the duration of the prefuse arc, which is arc discharge occurring from the
beginning until the fibers begin stuffing. Longer [Prefuse Time] is
synonymous with higher [Prefuse Power].
Overlap
Sets the overlap amount of fibers at the fiber stuffing stage. Relatively small
[Overlap] is recommended if the [Prefuse Power] is low, while relatively large
[Overlap] is recommended if the [Prefuse Power] is high.
Arc
Arc1 Power
Arc discharge can be separated into two stages. Arc1 Power is the first stage.
This sets Arc1 Power.
Arc1 Time
Sets Arc1 time.
Caution If Arc1Time is set 1 sec. or less and Arc2 Power is set to "OFF", the
splice may break during proof-test stage.
Arc2 Power
Arc2 is the second arc discharge stage. This sets Arc2 Power.
Arc2 Time
Sets the total Arc2 time. Usually set this value to “OFF”. It is possible to set a
very long arc time. However, when the total of the Arc 1 time and Arc2 time
exceeds 30 seconds, always adjust the function [Arc2 ON Time] and [Arc2
OFF Time] to weaken the arc power. A continuous arc over 30 seconds,
without weakening the arc power, may damage the arc discharge unit.
Arc2 On-Time
During Arc2 discharge, arc power can be pulsed by turning the arc on and off.
This sets the amount of time that Arc2 is ON.
Arc2 Off-Time
Sets Arc2 OFF Time during Arc2. When the Arc2 discharge is intermittent,
re-arc discharge is also intermittent. When continuous re-arc discharge is
necessary, set this parameter to “OFF”.
Tapering
Taper Splice
Splice loss is sometimes improved when the fiber is tapered (pulled) during
arc discharge to make the splice thinner. This sets taper function "ON". The
following three parameters determine the taper shape.
Taper Wait
Sets the taper wait time from the end of fiber stuffing until the start of pulling
fiber.
Taper Speed
Sets the fiber pulling speed.
Taper Length
Sets the fiber pulling length.