70S_Rev1
69
Heater Menu
Referring to or Editing Heater Mode
Tube-heating conditions stored in heater mode can be edited or changed.
1. Move cursor and select a mode to be edited in [Select Heater Mode] menu. Press
MENU key to display [Edit Heater Mode] menu.
2. Press Up/Down Arrow keys to move cursor to a parameter to be changed then press
ENT key to enter.
3. Change value by pressing Up/Down key, then press ENT key to enter.
Heater mode parameters
Parameter
Description
Sleeve type
Sets sleeve type. List of all heating modes are displayed. Select a mode in
the list and this is copied to a user-programmable mode.
Mode Title1
Title of a heater mode that is displayed in the lower right part of the monitor
during the splicing/heating process. Max number of characters used is 7.
Mode Title2
Description of a heater mode in the [Sleeve Type] screen. Max number of
characters used is 15.
Heat Time
Sets heating time from the beginning to the end (cool-down completion).
Heating time is automatically adjusted with atmospheric conditions, such as
ambient temperature. Heating time may be longer or shorter than [Heat
time] set.
Heat
Temperature
Sets heating temperature.
Finish
Temperature
Sets the finish temperature. The buzzer beeps after completion of the
heating.
Caution
Do not touch the shrunken sleeve after removing the fiber from the tube
heater. It may be hot. Hot sleeves easily deform and can cause some
residual stress at the splice point. Use J-plate to cool down the sleeve.
Up/Down Arrow key
ENT key
ENT key
Up/Down Arrow key
ENT key