70S_Rev1
80
Maintenance
Machine Settings
The parameter about warning and a maintenance item can be changed.
1. Select [Machine Settings] in [Maintenance Menu] to display [Machine Settings]
menu.
2. Select a parameter to be changed. Press ENT key to change values.
3. Change value by pressing Up/Down key, then press ENT key to enter.
Available to set the parameters about warning and maintenance item.
Parameter
Description
Basic Settings
Language
Sets a language to be displayed on the screen. Select a language to
be displayed. The language that can be displayed changes by a
software version and region code.
Buzzer Volume
Sets the sound volume of the buzzer.
Monitor Position
Sets the operational direction of splicer. [Front] is for front monitor
operation. [Rear] is for rear monitor operation. [Auto] is switched to
front monitor operation or rear monitor operation automatically. Refer to
next page for detail.
Power Saving Timer
Sleep(Battery)
Setting Sleep function turns off the power supply to the LCD
Monitor if the splicer performs no operation after a certain period of
time. Automatically turns off the power supply to the splicer if it
performs no operation for a certain period of time. The function serves
to prevent the battery capacity from running low if the splicer is left on
for an extended period of time.
Shut Down(Battery)
Sleep(AC)
Shut Down(AC)
Power On Option
Opening Title 1
Sets the message to be displayed when the splicer power is turned on.
Max number of characters: 15
Opening Title 2
Electrode
Electrode Caution
When the number of splices exceeds the selected [Electrode Caution]
value, the caution message prompting the operator to replace the
electrodes is displayed when the splicer power is turned on.
When the number of splices exceeds the selected [Electrode Warning]
value, the caution message changes to the warning message.
Electrode Warning
Cleave Blade Aram
Blade Position
Change
ON/OFF setup of the warning of the Cleaver counter can be performed.
In OFF, warning is not indicated on a screen.
Blade Height
Change
Blade Replacement
Arc Calibration
Cleave Limit
Sets the threshold of cleave angle error for the [Arc Calibration].
Max Number of
Tests
Sets the number which ends an inspection compulsorily for the [Arc
Calibration].