70S_Rev1
85
Error Message List
Error
Message
Reason
Solution
Large
Cleave
Angle
・
Bad fiber
end-face.
・
Check the condition of the fiber cleaver. If the blade is
worn, rotate the blade to a new position.
・
[Cleave Limit] is
set too low.
・
Increase the [Cleave Limit] to an adequate limit.
Large
Fiber
Angle
・
Dust or dirt is on
the V-groove or
the clamp chip.
・
Clean the V-groove and clamp chip, and set the fibers
again. If the error occurs again, strip, clean and cleave
the fibers.
・
Bad fiber
end-face.
・
Check the condition of fiber cleaver. If the blade is worn,
rotate the blade to a new position.
Cleave
Shape NG
・
Bad fiber
end-face.
・
Check the condition of fiber cleaver. If the blade is worn,
rotate the blade to a new position.
Arc
Discharge
Delayed
・
Arc Discharge is
delayed
・
Assure the electrodes are in proper position.
・
Execute the [Stabilize Electrode] function.
・
Replace the electrodes.
Thin Fiber
・
Inadequate arc
power
・
Calibrate the arc power with the [Arc Calibration]
function.
・
Prefuse power or
time is set too
high
・
If using the Other mode, adjust or initialize [Prefuse
Power] or [Prefuse Time] settings. For normal splice
mode, the prefuse is fixed and cannot be adjusted.
・
Insufficient
[Overlap] setting
・
If using the Other mode, adjust or initialize [Overlap]
setting. For normal splice mode, the overlap is fixed and
cannot be adjusted.
・
Execute [Motor Calibration] function in the maintenance
menu to calibrate the stuff amount.
Fat Fiber
・
Too much
[Overlap] setting
Too
Tapering
Fiber
・
Too much fiber
taper.
・
If using the taper splice function, the error message may
appear meaning the fiber is tapered too much.
Bubble
・
Bad fiber
end-face.
・
Check the condition of fiber cleaver. When the blade is
worn, rotate the blade.
・
Prefuse power or
time is set too low
・
If using the Other mode, adjust or initialize [Prefuse
Power] or [Prefuse Time] settings. For normal splice
mode, the prefuse is fixed and cannot be adjusted.
Large Dust
Burn
・
Bad fiber
end-face.
・
Check the condition of the fiber cleaver. If the blade is
worn, rotate the blade to a new position.
・
[Cleaning Arc]
time is too short
or “OFF.”
・
Dust still present after cleaning fiber or cleaning arc.
Clean fiber thoroughly or Increase [Cleaning Arc Time]