28
Basic Operation
2.
Inserting Power Supply to Splicer
For AC operation or DC operation with external battery, use AC adapter (ADC-13). For
battery operation, use detachable battery (BTR-08). The Power Unit Dock, located on the
splicer body, can accommodate both power supplies (ADC-13 and BTR-08).
2-1.
Inserting or detaching power unit
Inserting power supply unit
Insert power unit into Power unit dock until it clicks
into place.
Detaching power supply unit.
Turn off the splicer before removing the power unit.
Press the release button, located on the side of the
splicer body, and remove the unit from the other side
of the release button.
2-2.
AC Operation
Plug the supplied AC cord into the AC inlet of the AC
adapter. The power ON LED in the AC adapter turns on
(green color) when suitable AC voltage is supplied. If
high AC Voltage is supplied, the AC adapter will
immediately be damaged.
AC generators commonly produce abnormally high AC
output voltage or irregular frequencies. Measure the
output AC voltage with a circuit tester before connecting
the AC power cord.
Such abnormally high voltage or frequency from a generator may cause fuming, electric
shock or equipment damage and may result in personal injury, death or fire. Make sure
the generator is regularly checked and serviced.
Insert
Release button
Insert
Power ON LED
(Green)