63
Splice Menu
1-3.
Referring or editing splice mode
Splicing parameters in each splice mode can be
modified. Arc power and Arc time are considered
the two most vital parameters. To edit parameters
follow below steps:
(1) In [Select Splice Mode] menu, move cursor to a
splice mode to be modified. Press Menu key to
display [Edit Splice Mode] menu.
(2) Move cursor by pressing Up/Down Arrow key to
a parameter to be changed.
(3) Press Enter key to select parameter.
Press Up/Down Arrow key to change its values.
Press Enter key to accept changed values.
Below is a figure showing the Arc discharge conditions (relationship between "Arc
power" and "Motor motion"). The conditions can be edited by changing the splicing
parameters listed below. Depending on splice mode, certain parameters cannot be
changed.
A: Prefuse Power,
B: Arc1 Power,
C: Arc2 Power,
D: Cleaning Arc,
E: Prefuse Time,
F: Forward Time related to Overlap,
G: Arc1 Time,
H: Arc2 ON Time,
I: Arc2 OFF Time,
J: Arc2 Time,
K: Taper Wait Time,
L: Taper Time related to Taper Length,
M: Taper Speed,
N: Rearc Time
Motor
move
F
M
Arc
discharge
D E
G
J
H
I
C
N
A
B
L
K
UP/DOWN Arrow key
Menu key