85
Setting Menu
Parameter Description
Ignore Splice Error
Loss
Bubble
Fat
Thin
Fiber Angle
Setting to “Disable” prevents the splicer from normally finishing
its operation even if the message “Loss Error,” “Bubble Error,”
“Fat Error” “Thin Error” or “Fiber Angle Error” is disregarded.
Cleave
Setting to “Disable” prevents the splicer from continuing a splice
even if the message “Cleave Angle Error” is disregarded.
Fiber Image on Screen
Gapset
Pause1
Align
Pause2
Arc
Estimate
Finish
Sets the method of displaying the fiber image on the screen
during
Splicing operation.
X
: Enlarged display of X-axis image
Y
: Enlarged display of Y-axis image
X
▲▼
Y : Composite display vertically of X-axis and Y-axis
images
DATA : Display result of cleave angle and offset.
Others
Auto Fiber
Forward
If “Auto Fiber Forward” is set to “ON”, fibers are automatically
moved closer to gapset as soon as wind protector is closed.
Max. Num. Of
Rearcs
The re-arcing process sometimes improves the splice loss, but
sometimes worsens it. Re-arcing decreases the splice strength.
With this function, it is possible to limit the number of re-arcs or
to disable re-arc discharge.