4

Lamp Switch

High Switch

Medium Switch

Low Switch

OFF Switch

Pilot Lamp

Fan Switch
(Right)

Fan Switch

(Left)

Front Cover

Enclosure

Filter

Lamp (Not supplied)

(PAR20 bulb, in the base diameter

26mm: medium base)

Lamp Switch

Name of parts

Operating the Range Hood

 

 

 

 

 

 Control Switches

1

Push one of the switches ( ,  , 

) according to your cooking need.

The fan will start rotating. You can use the left and right fans simultaneously or
independently.

1 burner
2 burners or more
3 burners or more
all burners

1 (above the burner)
2 (Left and right fans) 
2 (Left and right fans)
2 (Left and right fans)

  (Low),   (Medium), or    (High)

   (Medium), or     (High) 
     (High)

Switch(es) to be used

No. of fan(s) to be operated

No. of burner(s) in use

 (Low)

For light cooking

 (Medium)

Normal position

 (High)

For heavy cooking (3 or more burners)

2

To stop the fan, just push off switch.

3

Turn the light switch clock-wise to turn the lights on. Will make lights brighter.
To turn the lights off, rotate the switch counter clock-wise until it clicks.

The range hood has nine controls on its front cover.
(One rotary switch for the lamps, four push switches for the left and right fan motors.)

Summary of Contents for BUF-08P

Page 1: ...uctions 2 Name of Parts 4 Operating the Range Hood 4 How to Use 5 Care and Maintenance 6 Disassembling 7 Cleaning 7 Re assembling 7 Replacing the Light Bulb 8 Requesting Service 9 Prior to Requesting Service 9 Inspection Label 9 Specifications 10 Circuit Diagram 10 Parts List 11 Limited Product Warranty 12 Operation Manual RANGE HOOD MODEL BUF 08W BUF 08P ...

Page 2: ...ISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flambeing foods i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe c Clean ventilating fans frequently Grease should not be allowed to accumulat...

Page 3: ...sult in personal injury or damage to property 1 For general ventilating use only Do not use to exhaust hazardous or explosive material and vapors 8 To protect hands from injury from the edges of the sheet metal wear working gloves while servicing means prohibition It indicates actions if any that mustn t be done means forcible execution It indicates actions if any that must be done NOTE The safety...

Page 4: ...ore 3 burners or more all burners 1 above the burner 2 Left and right fans 2 Left and right fans 2 Left and right fans Low Medium or High Medium or High High Switch es to be used No of fan s to be operated No of burner s in use Low For light cooking Medium Normal position High For heavy cooking 3 or more burners 2 To stop the fan just push off switch 3 Turn the light switch clock wise to turn the ...

Page 5: ...nge hood immediately if a fire occurs while cooking Continued operation of the range hood will add intensity to the fire How to use Before operating the unit make sure that the screws of the filters are tightened securely CAUTION More than 3 burners All burners Do not push more than one control switch at a time as it may cause failure To avoid failure of the range hood by overheating observe the f...

Page 6: ...l For safety always wear working gloves safety glasses or goggles while cleaning the filter etc Keep other people at a safe distance when cleaning to avoid injury from unexpected falling of filter or splashing of detergent CAUTION Do not splash water on the electrical parts such as the switches motors or connectors Do not use a spray type detergent to clean electrical parts It may cause electrical...

Page 7: ... remove dirt Clean the filter frequently to avoid grease build up which is difficult to clean Front Cover After wiping the front cover off with a cloth immersed in a mild detergent wipe off moisture thoroughly with a dry cloth Do not accessably rub the front cover as it may cause damage to coating Re assembling Re assembly will be done by following the disassembly procedure in reverse order descri...

Page 8: ... 120V 50Watt or below The following light bulbs are recommended for this range hood GE Model No 50PAR20H FL25 SYLVANIA Model No 50PAR20 HAL DL NFL To remove the light bulb turn it counter clock wise Replace the light bulb by turning it clock wise NOTE When replacing the bulb wait until it has cooled off before removing or injury may result To remove the light bulb To install the light bulb ...

Page 9: ...ne 1 888 547 9880 After Service Division Telephone 1 866 FUJI IND 1 866 385 4463 a Product Range Hood b Model Number BUF 08W BUF 08P c Serial Number d Date of purchase e What is the problem f Owner s address g Owner s telephone number h Suggested date for service person s visit Situation Check Range Hood does not operate Is power switch on at the service breaker Range Hood is noisier than usual Is...

Page 10: ... Black Black Grey Grey Grey Grey Black Black Yellow Yellow Yellow Black Black Pilot Lamp Pilot Lamp Lamp 50W Lamp 50W Lamp 50W Fan Switch Fan Switch Capacitor Lamp Switch Purple Purple Purple Refer to the following table NOTE FUJI INDUSTRIAL CO LTD has measured airflow under HVI 916 and noise levels under Japanese Industrial Standard JIS C9603 items 8 8 and 8 9 Model Voltage Frequency Speed Power ...

Page 11: ...it Wire Box Unit Earth Wire Unit Fan Unit Case Motor Sirocco Fan Bellmouth Filter Attachment 5 1 2 3 4 5 6 7 8 9 10 11 12 Attachment Name of parts Figure BUF 08W BUF 08P Four 4 Pieces Four 4 Pieces Mounting Bracket Screw M5 30 Screw M4 5 45 Four 4 Pieces M5 Nut with plate Figure Four 4 Pieces One 1 Piece Four 4 Pieces Parts list ...

Page 12: ...states do not allow the exclusion of incidental or consequential damages In that case the above limitation may not apply to you This warranty gives the original purchaser consumer specific legal rights and there may also be other rights that vary from state to state This warranty supersedes all prior warranties To qualify for warranty service first 1 Notify Fujioh at the address shown below or tel...

Page 13: ...ité 2 Nomenclature 4 Fonctionnement de la hotte d aspiration 4 Utilisation 5 Entretien et maintenance 6 Démontage 7 Nettoyage 7 Remontage 7 Remplacement de l ampoule 8 Recours au service après vente 9 Avant de faire appel au SAV 9 Etiquette d inspection 9 Fiche technique 10 Schéma de câblage 10 Liste des pièces 11 Garantie 12 Hotte D aspiration MODE D EMPLOI MODÈLE BUF 08W BUF 08P ...

Page 14: ...tés de surface sans surveillance sur grand feu Les débordements peuvent provoquer de la fumée et des dépôts huileux qui peuvent s enflammer Chauffez l huile sur feu doux ou moyen b Mettez toujours la hotte sous tension lorsque vous cuisinez à grand feu ou lorsque vous flambez un plat par ex Crêpes Suzette Cerise jubilé Steak au poivre flambé c Nettoyez fréquemment les ventilateurs La graisse ne do...

Page 15: ...ut provoquer des blessures personnelles ou des dégâts matériels 1 Pour ventilation générale uniquement Ne pas utiliser pour évacuer des substances ou des vapeurs dangereuses ou explosives 8 Mettez des gants de travail lorsque vous procédez aux réparations pour éviter de vous couper avec les bords des parties métalliques signifie interdiction Indique des actions qui ne doivent pas être effectuées s...

Page 16: ... Boutons de commande 1Appuyez sur le bouton du ventilateur Bas ou Haut qui convient à vos besoins en cuisson Les ventilateurs droit et gauche sont utilisables simultanément ou indépendamment Bas Pour les préparations légères Moyen Position habituelle Haut Pour les préparations 3 brûleurs ou plus 2 Pour arrêter le ventilateur appuyez simplement sur le bouton d arrêt 3 Tournez le bouton lumière dans...

Page 17: ... il se produit un feu lorsque vous cuisinez L intensité du feu augmentera si vous continuez à utiliser la hotte d aspiration Utilisation Avant l utilisation assurez vous que les vis du filtre et du couvercle de lampe sont bien serrées à fond PRÉCAUTION 3 brûleurs ou plus tous les brûleurs Ne poussez pas simultanément plus d un bouton de commande car une panne est possible Pour éviter une panne de ...

Page 18: ...panneau de service Par mesure de sécurité mettez toujours des gants de travail et des lunettes de protection lorsque vous nettoyez le filtre etc Eloignez les autres personnes lorsque vous nettoyez pour éviter toute blesser par chute accidentelle du filtre ou éclaboussement de détergent PRÉCAUTION N éclaboussez pas les pièces électriques comme le moteur les interrupteurs et les connecteurs avec de ...

Page 19: ...t similaire pour retirer la saleté Nettoyez le filtre fréquemment de façon à éviter tout dépôt de graisse qui sera difficile à nettoyer Couvercle avant Après avoir essuyé le couvercle avant avec un chiffon imbibé d un détergent doux essuyez soigneusement avec un chiffon sec Ne frottez pas excessivement le couvercle avant car cela pourrait endommager le revêtement Remontage Le remontage se fait en ...

Page 20: ...oules suivantes sont recommandées pour cette hotte d aspiration Modèle n 50PAR20H FL25 de GE Co Modèle n 50PAR20 HAL DL NFL de SYLVANIA Co Pour retirer l ampoule tournez la dans le sens inverse des aiguilles d une montre Puis remplacez l ampoule par une neuve REMARQUE Lorsque vous remplacez l ampoule attendez qu elle ait refroidi avant de la retirer sinon vous risquez de vous brûler les doigts Pou...

Page 21: ...près vente Téléphone 1 866 FUJI IND 1 866 385 4463 a Produit Hotte d aspiration b Numéro de modèle BUF 08W BUF 08P c Numéro de série d Date d achat e Quel est le problème f Nom du propriétaire g Numéro de téléphone du propriétaire h Date suggérée pour la visite du réparateur Etiquette d inspection Le numéro de modèle et le numéro de série sont indiqués sur l étiquette d inspection qui est fixée à ...

Page 22: ...Noir Noir Jaune Jaune Jaune Noir Noir Lampe Pilote Lampe Pilote Lampe 50W Lampe 50W Lampe 50W Bouton de ventilateur Bouton de ventilateur Capacitor Bouton de lampe Pourpre Pourpre Pourpre Reportez vous au tableau suivant REMARQUE FUJI INDUSTRIAL CO LTD a mesuré le débit d air selon HVI 916 et les niveaux de bruits conformement aux rubriques 8 8 et 8 9 des Normes industrielles japonaises JIS C9603 ...

Page 23: ...es commutateurs Unité de boite de câblage Fil de terre Châssis du ventilateur Moteur Ventilateur Evasement Filtre Pièces de fixation 5 1 2 3 4 5 6 7 8 9 10 11 12 Pièces de fixation Nom des pièces Schéma BUF 08W BUF 08P Quatre 4 Quatre 4 Etrier de montage Vis M5 30 Vis M4 5 45 Quatre 4 Ecrous avec plaque M5 Schéma Quatre 4 Une 1 Quatre 4 Liste des pièces ...

Page 24: ...DE CE PRODUIT Certains états ne permettent pas l exclusion des dommages fortuits ou conséquents Dans ce cas les limites indiquées ci dessus ne peuvent pas s appliquer pour vous La présente garantie donne à l acheteur initial consommateur des droits légaux spécifiques et également d autres droits qui peuvent varier selon les états Cette garantie annule toutes les garanties précédentes Pour être hab...

Reviews: