background image

7

Knob

Filter

disassembling

1

Rectifier Baffle Panel

After loosening 2 screws fixing the
rectifier baffle panel, slide the panel to
dislocate the keyholes from the screws.
Then, open the panel a little and pull it
to remove from the catches.

NOTE

: As the rectifier baffle panel may

have grease built-up, be careful
about oil-drips when removing it.

2

Filter

First, turn the knob counter-clockwise,
then detach the filter with sliding it in
the direction of the arrow to disengage
from the groove.

cleaning

Filter

After immersing the filter in water with a mild
detergent for 30 to 40 minutes, wash it with
a toothbrush or the like to remove dirt. Clean
the filter frequently to avoid grease
contamination and grease build-up, which
is difficult to clean.

Enclosure/Rectifier Baffle Panel

After wiping the enclosure and rectifier baffle
panel off with a cloth immersed in a mild
detergent, wipe off moisture thoroughly with
a dry cloth.

Summary of Contents for ECP-360

Page 1: ...Operation Manual RANGE HOOD ...

Page 2: ...ISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flambeing foods i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe c Clean ventilating fans frequently Grease should not be allowed to accumulat...

Page 3: ... filter and other parts securely Incorrect attachment may result in personal injury or damage to property 1 For general ventilating use only Do not use to exhaust hazardous or explosive material and vapors 7 To protect hands from injury from the edges of the sheet metal wear working gloves while servicing means prohibition It indicates actions if any that mustn t be done means forcible execution I...

Page 4: ...4 Control Switches Lamp Switch High Switch Medium Switch Low Switch OFF Switch Pilot Lamp Lamp Not supplied Duct Cover Enclosure ...

Page 5: ...ectly it may become detached and fall down Do not touch the lamps or their peripheral areas when they are ON or your hand may be burned as they get overheated Do not use a gas range with nothing on the burners Otherwise the range hood could become overheated and it might be a cause of failure Stop running the range hood immediately if a fire occurs while cooking Continued operation of the range ho...

Page 6: ...off the breaker of service panel For safety always wear working gloves safety glasses or goggles while cleaning the filter etc Keep people away when cleaning to avoid injury from unexpected falling of parts or splashing of detergent CAUTION Do not splash water on the electric parts such as the switch or connectors Do not use a spray type detergent to clean electric parts It may cause trouble Do no...

Page 7: ...rn the knob counter clockwise then detach the filter with sliding it in the direction of the arrow to disengage from the groove cleaning Filter After immersing the filter in water with a mild detergent for 30 to 40 minutes wash it with a toothbrush or the like to remove dirt Clean the filter frequently to avoid grease contamination and grease build up which is difficult to clean Enclosure Rectifie...

Page 8: ... has cooled off before removing or you may burn your hand To remove the light bulb To install the light bulb re assembling 1 Filter Place the filter in the groove hold it upward and turn the knob clockwise to fix it securely 2 Rectifier Baffle Panel With holding the rectifier baffle panel by both hands place it on the catches Push the panel upward and slide it to engage the keyholes with 2 screws ...

Page 9: ...ristensen Rd Ste 212 Seattle WA 98188 3403 Telephone 1 888 547 9880 After Service Division Telephone 1 866 FUJI IND 1 866 385 4463 a Product Range Hood b Model Number ECP 360 c Serial Number d Date of purchase e What is the problem f Owner s address g Owner s telephone number h Suggested date for service person s visit Situation Check Range Hood does not operate Is power switch on at the service p...

Page 10: ...onnector Connector Connector Motor Red Orange Orange White White White Purple Purple White White White White Black Green Blue Blue Brown Brown Black Black Black Black Black White Black Black Grey Grey Grey Yellow Yellow Yellow Pilot Lamp Lamp Lamp Fan Switch Lamp Switch Capacitor Refer to the following table NOTE FUJI INDUSTRIAL CO LTD has measured airflow under HVI 916 and noise levels under Japa...

Page 11: ...ox Unit Filter Rectifier Baffle Panel Exhaust Pipe Unit Mounting Bracket Outer Duct Inner Duct Outer Frame Inner Frame Attachment 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 15 18 16 15 16 17 14 1 14 13 10 3 8 2 9 11 12 4 5 6 7 19 Attachment Name of parts Figure Four 4 Pieces Eight 8 Pieces Screw M5 10 Screw M5 1 45 parts list ...

Page 12: ...ome states do not allow the exclusion of incidental or consequential damages In that case the above limitation may not apply to you This warranty gives the original purchaser consumer specific legal rights and there may also be other rights that vary from state This warranty supersedes all prior warranties To qualify for warranty service first 1 Notify Fujioh at the address shown below or telephon...

Reviews: