background image

Inner duct

Outer duct

Roller catch

Slit

Hook

Hook

Ceiling

Inner duct

Inner frame

1

1

2

2

3

Inner duct

Inner frame

Ceiling

3-9/16"

(90)

3-9/16"

(90)

1-9/16"(40)

5-7/8"

(150)

8-11/16"

(220)

4-

9/16"(

14)

1-3/16"

(

30)

Beam

Front

Stringpiece

11"(280)

14-3/16"(360)

3-9/16"

(90)

3-9/16"

(90)

6-15/16"(  176)

11-13/16"(300)

46-7/8"(1190) MAX Height

13"(330)

23-5/8"(600)

33"(837.5) MIN Height

3-1/8"(80)  

14-3/16"(360)

16-5/8"(422)

15-3/4"(400)

16-1/8"(409)

16-7/8"(428)

19-3/16"(487.4)

13-7/8"(352.5)

5-7/8" (150)

30"(762) MAX Duct Height

Stroke

Duct Cover 

(Outer)

Duct Cover (Inner)

7" (177.5)

1" (25)

36"(913)

24"(610)

18"(457)

1" (26)

Roof cap

7" round duct
(For vertical discharge)

Range hood

Lamp Switch

High Switch

Medium Switch

Low Switch

OFF Switch

Pilot Lamp

Control Switches

Lamp

(Not supplied)

Fan

Inner Duct

Inner Duct

Inner Frame

Outer Frame

Hanging
Bracket

Outer  Duct

Outer  Duct

Filter

Rectifier Baffle Panel

INSTALLATION MANUAL

Model: ECP-360

1U03 1881

Before installation and operation, read these instructions carefully
and use this product only in the manner described by the
manufacturer in the operation manual.
The instruction shown below are used to alert you to potential
personal injury and property damage hazards.
There are three hazard classifications based on potentially
dangerous situations.
Obey all safety instructions that show these symbols to avoid
possible injury, death and property damage.

SAFETY INSTRUCTIONS

WARNING:

WARNING indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.

CAUTION:

CAUTION indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.

Screw

Inner frame

Outer frame

5

_

(1)

5

(1) Pull out the inner frame after removing 4 screws fastening to the

outer frame.

Note:

Keep the screws for reusing later.

(2) Fix the inner frame to the ceiling using

8 wood screws supplied after aligning
its holes with the threaded rods.

NOTE

: The safety instructions are explained with the following

pictographic symbols.

means forcible execution. It indicates actions, if
any, that must be done.

 WARNING

1. TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:

a) Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the
manufacturer.

b) Before servicing or cleaning the unit, switch power

off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.

  CAUTION

INSTALLATION

1. Preparation

3. Connecting Power Supply Wires

1

Remove the nut from the conduit
connector at the end of power
wiring.

2

Remove two screws fixing the wire cover and detach it.

5. Assembly and Check

2

Two 50 W halogen light bulbs (not supplied)
can be mounted in this range hood.
Prior to function check, install light bulbs
(PAR20 bulb, in the base diameter 26 mm:
medium base), rated 120 V - 50 W or below.

Turn the lamps clockwise
to install them.

Range Hood

3. Read specification label on this product for further

information and requirements.

2. To reduce the risk of fire and to properly exhaust

air, be sure to duct air outside. Do not vent exhaust
air into spaces within walls, ceilings or into attics,
crawl spaces or garages.

6. Fasten the filter and other parts securely. Incorrect

attachment may result in personal injury or
property damage.

4. Use only for the purpose of kitchen ventilation.

1. For general ventilating use only. Do not use to

exhaust hazardous or explosive material and
vapors.

5. Do not install this range hood in the bathroom or

in other wet rooms since electrical shock and
damage may result.

2. To reduce the risk of fire or electric shock, do not

use this product with any solid-state speed control
device.

b) Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guidelines and safety standards such as those
published by the National Fire Protection
Association (NFPA), and The American Society
for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.

c) When cutting or drilling into wall or ceiling, do not

damage electrical wiring and other hidden utilities.

d) Ducted fan must always be vented to outdoors.

1

This range hood is designed to
install using anchor bolts as
illustrated and discharge upward.
For vertical discharge, run duct
work between the hood location
and roof cap location.
To get the best result, use a
minimum number of transitions
and elbows. Be sure to attach a
roof cap to avoid rain from
entering into the exhaust duct.

2

Referring to the figure below, make an opening on the ceiling and
reinforce around the opening with some beams. Then, make 5 holes
as shown in the figure.

   • Ensure that the metal duct does not touch other metal housing materials,

otherwise fire or electric shock could result.

   • Install the range hood unit using anchor bolts durable

enough to support its weight (withstand load: more than
441lbs. (200kg)/pc). Otherwise, it may be detached and
fall down.

6. Explanation to the End User

(1) Referring to the Operation Manual, explain the operation of this range

hood to the end user.

(2) The Installation Manual and Operation Manual should be given to the

end user.

Assembly

1

Attach the filters and rectifier baffle panel referring to the steps
described in “2. Range Hood Mounting”.

Check

1

Turn on the power to the range hood.

2

Make sure that the switches and light operate correctly.
Refer to page 4 of the Operation Manual.

3

Make sure that the range hood functions properly and it has no
abnormal noises and/or vibration.

   • Electrical wiring should be done by a qualified person(s) in accordance

with all applicable codes and standards, including fire-rated construction.
An unqualified person doing the work could result in fire, electric shock
or injury.

   • This range hood uses 120V AC. Do not connect to other voltage since

fire, electric shock or damage could result.

Be sure to switch OFF the power
at service panel before wiring.

3

Connect the conduit through the connecting hole of the body using the
nut previously removed.

4

Connect wires tightly and
securely using wire
connectors  (not supplied).
Connect the electrical wires
as follows:

5

Replace the wire cover with the
screws removed previously.
Make sure that all wires are
connected properly and
enclosed inside of the wiring
compartment.

CAUTION:

CAUTION used without the safety
alert symbol indicates a potentially
hazardous situation which, if not
avoided, may result in property
damage.

means prohibition. It indicates actions, if any, that
mustn’t be done.

4. TO REDUCE THE RISK OF FIRE, USE ONLY

METAL DUCTWORK.

5. This unit must be grounded.

CIRCUIT DIAGRAM

6. Check that the hood is correctly installed, since

incorrect installation could result in the range hood
becoming detached and falling off.

7. Connect only to an AC120 Volt power source or

the range hood could result in fire, electric shock,
and damage.

DIMENSIONS

CAUTION:

WARNING:

WARNING:

Unit: inch (mm)

NAMES OF PARTS

RANGE HOOD LOCATION

1

The range hood must be installed
just above the cooktop.

2

The minimum distance from the
cooking surface to the bottom of the
range hood must be 24".

3

The total weight of the ECP-360
range hood unit is 86.0 lbs. (39 kg)

4

Power requirements are:
AC120 V, 60 Hz, 3.0 Amp

   • Check that the hood is correctly installed, since incorrect installation could

result in the detachment of the range hood and the unit could fall down.

   • To protect hands from injury, wear working gloves when installing the

range hood.

CAUTION:

ACCESSORIES

24"(minimum)

Cook top

120V
60Hz

Connector

Connector

Connector

Connector

Connector

Connector

Motor

Red

Or

ange

Or

ange

White

White

White

White

White

White

Blac

k

Green

Blue

Blue

Bro

wn

Bro

w

n

Black

Purple

Purple

Black

Black

Black

Black

White

Black

Black

Grey

Grey

Grey

Yellow

Yellow

Yellow

Pilot Lamp

Lamp 50W

Lamp 50W

Fan Switch

Lamp Switch

Capacitor

3

Arrange the ends of 7” round duct and conduit so that they can connect
with the top of the range hood unit.

3. TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:

a) Installation work and electrical wiring must be

done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-
rated construction.

• Black to Black
• White to White
• Green to Green

WARNING:

6

With inserting the inner
frame into the outer
frame and the exhaust
port into the duct, lift up
the range hood unit and
pass the threaded rods
through the hanging
brackets as shown.

7

Fix the range hood unit
by adding 4 flange nuts
(not supplied) to the
threaded rods as shown.

Unit: inch (mm)

Duct

Conduit

Threaded rod

Inner Frame

Stringpiece

(Not Supplied)

40mm

Duct

Nut

Washer

Spring-
Washer

Ceiling

Beam

6

Secure the threaded rods by adding
washers, spring washers, and nuts
from the ends of the rods.

7

Set 4 flange-nut (not supplied) on the
threaded rods as shown for fixing the
supplied hanging brackets later.

50mm

Washer*

Inner Frame

Ceiling

Beam

Spring-Washer*

Nut*

*Not Supplied

Flange Nut

6

5

_

(2)

7

2. Range Hood Mounting

   • Wear working gloves to avoid injury.

CAUTION:

1

Detach the tape on the exhaust
port, then with paying attention to
the shutter opening direction, fix it
using screws attached on the top
plate.

2

Detach the rectifier baffle
panel by loosening 2 fixing
screws, sliding it to dislocate
the keyholes from the
screws, and disengage it
from the catches.

Rectifier

baffle panel

Loosen 2 screws
to remove the filter

2

Loosen 2 screws to remove
the rectifier baffle panel

Filter

3

3

Detach the filters by
turning the fixing
knobs counter-
crockwise, and
disengaging them
from the supporting
groove.

Hanging bracket

Outer frame

5

4

Screw

4

Attach the outer frame to the range hood unit using 4 screws supplied.

5

Attach 4 hanging brackets supplied to the range hood unit and fix them
as shown. As the fixing screws are attached on the top plate, remove
them once and use for fastening the hanging brackets.

Exhaust port

Inner frame

Outer frame

Flange nut

Duct

6

7

Note:

Check that the range hood unit is fixed at the specified height
horizontally and adjust if not.

Screw

8

9

Non-flammable tape

Conduit
(Not supplied)

Nut
(Not supplied)

8

Fasten the outer frame
and inner frame using
4 screws removed
before as shown.

9

Make the duct joint
secure and air-tight
using non-flammable
tape such as duct tape,
etc (not supplied).

Wire cover

Screw

Nut

Conduit

Wire connector

Wire cover

Screw

Push to turn ON

Bulb
(Not supplied)

Filter

Rectifier baffle panel

4. Attaching Duct Cover

1

Attach the inner duct (front and rear).
Insert the upper edge of the inner duct into the gap between the inner
frame and ceiling with sliding on the guide frame on both sides, then
push the front and rear ducts until they are fixed by their roller catch.

Note:

 Be careful not to attach the duct upside down.

2

Attach the outer duct (front and rear).
Place the outer duct on the range hood unit, and push the front and
rear ducts until they are fixed by their roller catch.

Note:

 Be careful not to attach the duct upside down.

3

Fix the outer duct (front and rear) to the range hood unit using 4 screws
supplied as shown.

 • Screw M5

×

10

Four (4) pcs.

 • Screw M5.1

×

45

Eight (8) pcs.

4

Pass 4 threaded rods*
(not supplied) through
the holes of the
ceiling and put
washers, spring
washers, and nuts on
the rods, then fix
them to the beam.
(*

12~14 anchor

bolt, length = duct
height - 40mm)

 • Exhaust Port

One (1) pc.

Exhaust port

Shutter

opening direction

Tape

 • Hanging Bracket

Four (4) pcs.

Reviews: