background image

Rectifier baffle panel

Filter

Loosen 2 screws
to remove the filter

2

3

Loosen 2 screws

to remove the

rectifier baffle panel

1

The range hood must be installed just above the
cooktop.

2

The minimum distance from the cooking surface
to the bottom of the range hood must be 24".

3

The total weight of the range hood units are as
follows;

4

Power requirements are:
ECW-300: AC120 V, 60 Hz, 2.5 Amp
ECW-360: AC120 V, 60 Hz, 3.0 Amp

1"

3-3/4"

13/16"

13/16"

9-1/16"

5-5/16"

14-3/8"

1-3/16"

16-3/4"

5"

16-1/8"~30"

30-1/2"~44-3/8"

9-7/16"

11"

30"

24"

18"

16-3/4"

1/4"

R1

/8"

R1

/4"

11"

4-

3/8" Holes for mounting range hood

ECW-300

5-7/8"

1-3/16"~

1-15/16"

A

B

Duct

Range hood

Center line

ECW-360

ECW-300

(Unit : inch)

A

B

5-7/8"

3-5/16"

5-5/16"

1"

INSTALLATION MANUAL

Model: ECW-300/360

1U03 1782

Before installation and operation, read these instructions carefully
and use this product only in the manner described by the
manufacturer in the operation manual.
The instruction shown below are used to alert you to potential
personal injury and property damage hazards.
There are three hazard classifications based on potentially
dangerous situations.
Obey all safety instructions that show these symbols to avoid
possible injury, death and property damage.

SAFETY INSTRUCTIONS

WARNING:

WARNING indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.

CAUTION:

CAUTION indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.

NOTE

: The safety instructions are explained with the following

pictographic symbols.

means forcible execution. It indicates actions, if
any, that must be done.

 WARNING

1. TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:

a) Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the
manufacturer.

b) Before servicing or cleaning unit, switch power

off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.

  CAUTION

INSTALLATION

1. Preparation

2. Range Hood Mounting

5

Tighten both the left and
right screws, and fix the
range hood securely
adding 4 more supplied
washer head wood
screws to the holes on
the hanger and back of
the range hood.

3. Connecting Power Supply Wires

1

Remove the nut from the conduit
connector at the end of power wiring.

2

Remove each screw fixing the
wire cover and detach it.

5. Assembly and Check

Two 50 Watt halogen light bulbs (not supplied) can be mounted in
this range hood.
Prior to function check, install light bulbs (PAR20 bulb, with base
diameter 26 mm: medium base), rated 120 V - 50 Watt or below.

The following light bulbs are recommended for this range hood.
• GE Model No. 50PAR20H/FL25
• SYLVANIA Model No. 50PAR20/HAL/DL/NFL

Turn the lamps clock-wise to install.

Range Hood

3. Read specification label on this product for further

information and requirements.

2. To reduce the risk of fire and to properly exhaust

air, be sure to duct air outside. Do not vent exhaust
air into spaces within walls or ceilings or into attics,
crawl spaces, or garages.

6. Fasten the filter and other parts securely. Incorrect

attachment may result in personal injury or
property damage.

4. Use only for the purpose of kitchen ventilation.

1. For general ventilating use only. Do not use to

exhaust hazardous or explosive material and
vapors.

5. Do not install this range hood in the bathroom or

in other wet rooms since electrical shock and
damage may result.

2. To reduce the risk of fire or electric shock, do not

use this product with any solid-state speed control
device.

b) Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guidelines and safety standards such as those
published by the National Fire Protection
Association (NFPA), and The American Society
for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.

c) When cutting or drilling into wall or ceiling, do not

damage electrical wiring and other hidden utilities.

d) Ducted fans must always be vented to the

outdoors.

e) This unit is designed for ducted or ductless

installation. When ductless kit part numbers
FDK-ECW300 (for model ECW-300), FDK-
ECW360 (for model ECW-360) is installed, this
unit is certified ductless. The end user is
responsible to ensure compliance with all Federal,
State and Local Environmental and Fire codes.

1

According to the conditions where
the range hood is installed,
determine whether it will be
discharged vertically or horizontally
(ECW-300: 6” round duct, ECW-
360: 7” round duct). For vertical or
horizontal discharge, run duct work
between the hood location and the
roof cap or wall cap.
For best result in either direction,
use a minimum number of
transitions and elbows. Be sure to
attach a roof cap or wall cap to
avoid rain/wind entry.

2

Referring to the figure right,
arrange the end of 6” or 7” round
duct just above the exhaust port of
the range hood unit.

   • If the range hood is not installed properly, it could become detached

and fall.

   • Ensure that the metal duct does not touch other metal housing

materials, otherwise fire or electric shock could result.

   • Install the range hood unit on a wall where durable

enough to support its weight. Otherwise, it may be
detached and fall down.
Reinforce the wall with some wood panel if necessary.

   • Wear working gloves to avoid injury.

CAUTION:

6. Explanation to the End User

(1) Referring to the Operation Manual, explain the operation of this

range hood to the end user.

(2) The Installation Manual and Operation Manual should be given to

the end user.

1

Assembly

Attach the filters and rectifier baffle panel referring to the steps
described in “2. Range Hood Mounting”.

2

Check

(1) Turn on the power to the range hood.
(2) Make sure that the switchs and light operate correctly.

Refer to page 4 of the Operation Manual.

(3) Make sure that the range hood functions properly and it has

no abnormal noises and/or vibration.

   • Electrical wiring should be done by a qualified person(s) in accordance

with all applicable codes and standards, including fire-rated
construction. An unqualified person doing the work could result in
fire, electric shock or injury.

   • This range hood uses 120V AC. Do not connect to other voltage since

fire, electric shock or damage could result.

Be sure to switch OFF the power
at service panel before wiring.

3

Connect the
conduit through
the connecting
hole of the
enclosure using
the nut previously
removed.

5

Replace the wire cover with the
screw(s) removed previously.
Make sure that all wires are
connected properly and
enclosed inside of the wiring
compartment.

3

Detach the filters by
turning the fixing
knobs counter-
clockwise, and
disengaging them
from the supporting
groove.

CAUTION:

CAUTION used without the safety
alert symbol indicates a potentially
hazardous situation which, if not
avoided, may result in property
damage.

means prohibition. It indicates actions, if any,
that mustn’t be done.

4. TO REDUCE THE RISK OF FIRE, USE ONLY

METAL DUCTWORK.

5. This unit must be grounded.

6. Check that the hood is correctly installed, since

incorrect installation could result in the range hood
becoming detached and falling off.

7. Connect only to an AC120 Volt power source or

the range hood could result in fire, electric shock,
and damage.

CIRCUIT DIAGRAM

CAUTION:

WARNING:

WARNING:

2

Detach the rectifier
baffle panel by
loosening 2 fixing
screws, sliding it to
dislocate the keyholes
from the screws, and
disengaging it from
the catches.

NAMES OF PARTS

RANGE HOOD LOCATION

   • Check that the hood is correctly installed, since incorrect installation could

result in the detachment of the range hood and the unit could fall down.

WARNING:

ACCESSORIES

 • Screw M4

×

10

Two (2) pcs.

 • Screw

M5.1

×

45

Four (4) pcs.

24"(minimum)

Cook top

Push to turn ON

3

Referring to “DIMENSIONS” above, insert
2 supplied wood screws into the mounting
wall for the left and right keyholes of the
hanger. Allow about 1/4” space between
the wall and screw-heads for hanging.

1/4"

4

With inserting the exhaust
port into the duct, hook
both the left and right
keyholes of the hanger on
the screws provided in
“Preparation” step 3.

6

Make the duct joint secure
and air-tight using non-
flammable tape such as duct
tape, etc. (Not supplied)

1

(1) Installing hanger

Put the supplied hanger
on the hood top, and fix it
using screws attached on
the top plate.

(2) Installing exhaust port

Detach the tape on the
exhaust port, then with
paying attention to the
shutter opening direction,
fix it using screws
attached on the top plate.

3. TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:

a) Installation work and electrical wiring must be

done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-
rated construction.

• Black to Black
• White to White
• Green to Green

WARNING:

Hanger

Tighten screws
to fix

Non-flammable tape

Conduit
(Not supplied)

Nut
(Not supplied)

Wire cover

Wire cover

Screw

ECW-300

ECW-360

Screw

Nut

Conduit

Wire connector

Wire cover

Hook

Wire cover

Screw

Screw

ECW-300

ECW-360

Filter

Rectifier baffle panel

Bulb
(Not supplied)

4. Attaching Duct Cover

1

Referring to “DIMENSIONS” and
“RANGE HOOD LOCATION” above,
calculate the duct cover height
necessary to cover between the
range hood top and ceiling.

2

For height adjustment, loosen 3
wing-bolts of the duct cover and pull
the inside slide cover up to the height
calculated.

3

Tighten 3 wing-bolts securely to fix
the inside slide cover.

Wing-bolt

2

Loosen

Fix

3

Hanger

Duct cover

Hanger

Duct cover

120V
60Hz

Connector

Connector

Connector

Connector

Connector

Connector

Motor

Red

Or

ange

Or

ange

White

White

White

White

White

White

Blac

k

Green

Blue

Blue

Bro

w

n

Bro

w

n

Black

Purple

Purple

Black

Black

Black

Black

White

Black

Black

Grey

Grey

Grey

Yellow

Yellow

Yellow

Pilot Lamp

Lamp 50W

Lamp 50W

Fan Switch

Lamp Switch

120V
60Hz

Connector

Connector

Connector

Connector

Connector

Connector

Motor

Red

Or

ange

Or

ange

White

White

White

White

White

White

Green

Blue

Blue

Bro

wn

Bro

w

n

Black

Purple

Purple

Black

Black

Black

Black

White

Black

Black

Grey

Grey

Grey

Yellow

Yellow

Yellow

Pilot Lamp

Lamp 50W

Lamp 50W

Fan Switch

Lamp Switch

ECW-360

ECW-300

Capacitor

Capacitor

Lamp Switch

High Switch

Medium Switch

Low Switch

OFF Switch

Pilot Lamp

Control Switches

Lamp
(Not supplied)

Fan

Duct Cover

Hanger

Filter

Rectifier Baffle Panel

ECW-300 50.7 lbs. (23kg)
ECW-360 70.5 lbs. (32kg)

DIMENSIONS

Unit: inch (mm)

2-5/8"

5-7/8"

13/16"

13/16"

15-1/16"

5-7/8"

16-7/8"

1-3/16"

19-3/16"

5"

16-1/8"~30"

33"~46-7/8"

11-7/16"

13"

36"

24"

18"

4-

3/8" Holes for mounting range hood

17"

ECW-360

16-3/4"

1/4"

R1/8"

R1

/4"

6-15/16"

4

Set the duct cover on the range hood unit, and fix it to the range
hood unit using 2 screws supplied.

4

Connect wires tightly and securely
using wire connectors
(not supplied).
Connect the electrical
wires as follows:

Round duct
(For vertical discharge)
(ECW-300=6"/ECW-360=7")

Range hood

Soffit

Roof cap

Round duct
(For holizontal discharge)
(ECW-300=6"/
ECW-360=7")

Wall cap

 • Hanger

One (1) pc./ea.

 • Exhaust Port

One (1) pc./ea.

Hanger

Exhaust port

Shutter opening

direction

ECW-360

ECW-300

Tape

(For ECW-300)

(For ECW-360)

 • Wood Screw

M4.5

×

45

Two (2) pcs.

7. Keep your hands and other objects away from

the fan while it is in motion. The range hood may
injure you or damage itself.

   • To protect hands from injury, wear working gloves when installing the range

hood.

CAUTION:

Reviews: