11
Installation
1F02 2881
3
Connection of duct and exhaust port
(FR-FS2270/90VP only)
Connect
∅
150 flexible tube duct or the like with
the supplied exhaust port.
Make the supplied exhaust port secure and air-
tight using non-flammable tape such as aluminium
tape, etc. (not supplied)
Note
The longer the exhaust duct, the lower the
ventilation.
Taping with non-flammable materials
(Aluminum tape, etc.)
Exhaust port
Flexible tube duct
Upper side-mounted Installation
Mounting bracket
1
Detach mounting brackets from the cooker
hood
Detach the two mounting brackets attached on the
upper side of the cooker hood.
After completing this process, proceed to
“Reattaching the removed parts” on page 13.
FR-FS2270/90VP
FR-FS2290RP
570/760
165
45
210
17
700/890
95
170
45
50
210
75
85
760
45
17
890
95
170
45
75
85
Make a hole
for the exhaust port
(Top view)
(Front view)
Make a hole
for the power cord
Make a hole
for the power cord
Cabinet
2
Make holes on mounting surface (cabinet)
Referring to the diagrams below, make holes on the mounting surface (cabinet) for the power cord and
the exhaust port (FR-FS2270/90VP only).