Colour monitor 21P4
A26361-K886-Z100-1-5E19
English - 17
Setting convergence (
Convergence
)
If objects on the screen have red or blue shadows, the convergence
of the monitor is incorrectly adjusted.
3
4
= Setting horizontal convergence
6
5
= Setting the vertical convergence
Setting advanced options (Advanced)
Calling the
Advanced
setting window
65
= Selecting function
Degaussing the monitor (
Degauss
)
When colour shifts occur in the screen display due to the influence
of magnetic fields (e.g. after transporting or turning the screen), the
screen must be degaussed.
Do not use the feature more than once within a 15-minute period!
Activating the factory settings (
Recall
)
Factory settings are provided for picture size, picture position and
geometry in the predefined operating modes.
3
= Rejecting function
4
= Activating factory settings
Setting entry level of video signal (
Video Input Level
)
If required, the entry level of the video signal can be changed from
0.7 V (default) to 1 V. If the monitor is operated on a PC, use the
default setting.
3
4
= Selecting entry level
Setting synchronisation (
Sync.
)
Input Type
)
This function allows you to set synchronisation – (depending on the
graphics card used).
3
4
= Selecting synchronisation type
Summary of Contents for 21P4
Page 2: ......