488
U41117-J-Z125-7-76
Message lines
Explanation of console messages
SXRD104
WARNING: raid 0:1:0 - Disk: Write-Only, 17300 MB
Meaning
A rebuild is active for the physical disk of controller 0, channel 1, target ID 0.
9.2.15.2
FibreCAT S80 messages
SXRD00<n>
s80d: RAID: <weight>: <raid-id> Raid<raid#> enclosure <shelf#> <component>
<status>
Meaning
If there is a status change in a S80 component, a message will be output on the console.
The terms used here have the following meanings:
n
1 - 8
weight
Error severity:
NOTICE
information
n=8,9
WARNING
soft error
n=6,7
ERROR
error
n=4,5
ALERT
critical error
n=2,3
raid-id
FibreCAT identification (target# of the 2 RAID controllers)
raid#
Number of the RAID system (1 – 8)
shelf#
Number of the shelf (1 – 7)
component
Internal component of the shelf
Disk drive (1 – 14)
Power supply (1 – 2)
Cooling fan (1 – 4)
Enclosure services module (1 – 2)
Loop monitor
Voltage sensor (1 – 6)
Current sensor (1 – 6)
Temperature sensor (1 – 4)
status
Status of the component
OK
Error corrected
Warning
Non-critical error (sensor only)
Critical
Critical error
Not Installed
Component removed or faulty
Not Available
Component not in operation
Unknown
Status not available (sensor only)
Summary of Contents for CentricStor V3.1D
Page 1: ...Edition July 2007 CentricStor V3 1D User Guide...
Page 22: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 60: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 236: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 311: ...U41117 J Z125 7 76 311 Global Status History diagrams Example for V3 1D...
Page 321: ...U41117 J Z125 7 76 321 Global Status History diagrams 4 Open history file...
Page 322: ...322 U41117 J Z125 7 76 History diagrams Global Status 5 Confirm you wish to open it...
Page 324: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 544: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Page 546: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...