Preliminary
29(36)
Prepared
Document Number
Manfred Ortmann
Approved
Checked
Date
Revision
Storage
2008-05-14
PA 3.5
Mycable01
2.2.11 Buttons
If the button SW100 which is not labeled will be pressed a reset will be generated.
If the button SW501 which is labeled with ABORT will be pressed the interrupt 0 ( P24_0 ) will
be generated.
If the button SW502 which is labeled with TEST1 will be pressed the interrupt 1 ( P24_1 ) will be
generated.
If the button SW503 which is labeled with TEST2 will be pressed the interrupt 7 ( P24_7 ) will be
generated.
If the button SW504 which is labeled with TEST3 will be pressed the interrupt 6 ( P24_6 ) will be
generated.
2.2.12 LEDs
The RESET LED ( D102 ) is on if the reset is active.
The 3.3V LED ( D106 ) is on if the 3.3 V power supply is on independent of the limits.
The 5.0V LED ( D107 ) is on if the 5.0 V power supply is on independent of the limits.
D500 and D503 are free usable LEDs.
A logical '0' switches the LED on. A logical '1' switches the LED off.