12.1. Accessories (Communication kit)

The following installation accessories are supplied. Use them as required.

Name and Shape

Q’ty

Description

Relay control board

1

For connecting the 
wired remote control 
unit and external 
connect wire.

Binder

1

For 

fi

 xing the wires 

from control box.

Relay wire

1

For connecting the 
relay control board and 
control unit board.

Wiring label

1

For display the additional 
wiring diagram.

12.2. Installation work

12.2.1. Removing intake grille and front panel 

(Refer to 9.1. intake grille removal and 9.3. front panel removal)

12.2.2. Removing control cover, connector and control box

Screw 1

Screw 2

Control cover

Earth (Ground) wire 
(Green)

Control box

Screw 3

CN5 (White connector)

CN4 (Red connector)

CN14 *1. 
(White connector)

CN7 
(White connector)

Connector wires

(CN4, CN5, CN7, CN14)

(1) Remove the screw 1 then remove the control cover.
(2)  Remove the connector wires.

*1. When there is CN14 connector, pull it out.

(3) Remove the connecting cables and the screw 2 and 3, then remove the control box.

11.  REMOTE CONTROLLER INSTALLATION

 CAUTION

Check that the indoor unit correctly receives the signal from the remote controller, 
then install the remote controller holder.
Select the remote controller holder selection site by paying careful attention to the fol-
lowing:
Avoid places in direct sunlight.
Select a place that will not be affected by the heat from a stove, etc.

11.1.  Remote controller holder installation

  Install the remote controller a maximum  distance of 6 m  from the remote control signal 

receiver. However, when installing the remote controller, check that it operates cor-
rectly.

  Install the remote controller holder to a wall, pillar, etc. with the tapping screw.

Remote controller 
holder 

fi

 xing

Remote controller 
mounting

Remote controller 
holder

Tapping 
screw 
(small)

(1) Set

Remote 
controller

(2) Down

12. OPTIONAL KIT INSTALLATION (UTY-TWBXF)

This air conditioner can be connected with the following optional kits.
 •  Wired remote controller
 •  Simple remote controller
 •  External connect kit

BEFORE INSTALL WIRED REMOTE CONTROLLER

 •  When you use wired remote controller, some functions may not be used.

 CAUTION

Before installing, be sure to disconnect all power supply.

Don’t touch the heat exchanger.

During installing or removing operation, be sure not to have wire caught by parts or 
draw it hard. Or it may result troubles to the air-conditioner.

Avoid place in direct sunlight.

Select place that will not be affected by the heat from a stove, etc

 Before setting up the optional kit, please con

fi

rm whether air-conditioner can receive 

the signal.

Do not connect the wired remote controller to the terminal for power supply.

 When connecting the wired remote controller with the indoor unit, use the connecting 
cable (supplied with wired remote controller or simple remote controller).

 Recommended cable length of wired remote controller is 10 m. Make sure to do insu-
late of connecting part when extended the cable.

Do not connect power supply with the terminal.

INDOOR UNIT

PCB

TERMINAL

9319357041_IM.indb   10

9319357041_IM.indb   10

11/30/2011   1:33:08 PM

11/30/2011   1:33:08 PM

Summary of Contents for 9319357041

Page 1: ...çais Español INSTALLATION MANUAL MANUEL D INSTALLATION MANUAL DE INSTALACIÓN For authorized service personnel only Pour le personnel agréé uniquement Solo para personal autorizado PART NO 9319357041 AIR CONDITIONER ...

Page 2: ... runs as short as possible Use the flare method for connecting tubing Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them then tighten the nut with a torque wrench for a leak free connection Check carefully for leaks before opening the refrigerant valves When Servicing Turn the power OFF at the main circuit breaker panel before opening the unit ...

Page 3: ...ket 1 Tapping screw big 5 Name and Shape Q ty Name and Shape Q ty Remote controller 1 Tapping screw small 2 Battery 2 Air cleaning filter 2 Seal A It is used when the diameter of gas pipe is Ø12 70 or more It is necessary when using AS15 1 The following items are necessary to install this air conditioner The items are not includ ed with the air conditioner and must be purchased separately Name Q t...

Page 4: ...such as storing food raising animals growing plants or preserving precision devices or art objects It can degrade the quality of the preserved or stored objects Do not install where there is the danger of combustible gas leakage Do not install the unit near a source of heat steam or flammable gas Install the unit where drainage does not cause any trouble Install the indoor unit outdoor unit branch...

Page 5: ... the outside with decorative tape For Left rear piping Left piping Interchange the drain cap and the drain hose CAUTION Insert drain hose and drain cap securely Drain should slope down to avoid water leakage When inserting be sure not to attach any material besides water If any other material is attached it will cause deterioration and water leakage After removing drain hose be sure not to forget ...

Page 6: ...an indicated in the table for flaring with R410A flare tools to achieve the specified flaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm in 6 35 1 4 17 21 32 9 52 3 8 22 7 8 12 70 1 2 26 1 1 32 15 88 5 8 29 1 5 32 19 05 3 4 36 1 13 32 6 9 2 Bending pipes If pipes are shaped by hand be careful not to collapse th...

Page 7: ...rminal block 5 Fasten the connection cable with a cable clamp Attach the 1 screw Insert the wire cover tab into the square hole of the indoor unit and fasten with a screw Cable clamp Connection cable Screw Screw Wire cover Connection cable Terminal block Cable clamp Connection cable Screw Screw Wire cover Earth Ground wire Earth Ground screw Indoor unit terminal block Disconnect switch Please conn...

Page 8: ...Connection cable Left piping For connection from the left rear PROHIBITED Pipe Connection pipe heat insulation Bind the pipes together so that there is no gap Indoor unit pipe heat insulation 7 4 How to connect wiring to the terminals Caution when wiring cable When stripping off the insulation of a lead wire always use a special tool such as a wire stripper If there is no special tool available ca...

Page 9: ... Center hooks 2 position Top hooks 2 position Top holes 2 position Indoor unit Front panel Bottom hooks 2 position Bottom hooks 2 position Front panel 2 Attach the 4 screws 3 Attach the wire cover Attach the 1 screw 4 Attach the intake grille CAUTION Install the Front panel and Intake grille securely If installation is imperfect the Front panel or Intake grille may fall off and cause injury 10 TES...

Page 10: ...controller holder installation Install the remote controller a maximum distance of 6 m from the remote control signal receiver However when installing the remote controller check that it operates cor rectly Install the remote controller holder to a wall pillar etc with the tapping screw Remote controller holder fixing Remote controller mounting Remote controller holder Tapping screw small 1 Set Re...

Page 11: ...ART STOP button until only the clock is displayed on the remote controller display 2 Press the MODE button for at least 5 seconds to display the current signal code initially set to 3 Press the SET TEMP buttons to change the signal code between Match the code on the display to the air conditioner signal code 4 Press the MODE button again to return to the clock display The signal code will be chang...

Page 12: ... to the installation conditions Incorrect settings can cause the indoor unit to malfunction After the power is turned on perform the FUNCTION SETTING according to the installation conditions using the remote controller The settings may be selected between the following two Function Number or Setting Value Settings will not be changed if invalid numbers or setting values are selected Refer to the i...

Page 13: ...nsor error 4 2 Indoor unit Heat Ex Middle temp sensor error 5 1 Indoor unit fan motor error 5 3 Drain pump error 5 7 Damper error 5 8 Intake grille error 5 15 Indoor unit error 6 2 Outdoor unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit er ror 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discha...