Installing the Printer
Installation of F9811 – ATB Printer
1. Environment for installation
Power supply
Temperature / Humidity
Altitude
Wide range 100 – 240 VAC at 50 Hz / 60 Hz
160W in printing and 58W in idling
5 -- 35
℃
/ 30 -- 85%RH at operation
- 5 -- 50
℃
/ 5 -- 95%RH at storage
0 – 4,000 m altitude
during operation
2. Cables
Power cable and communication cable have to be provided as these are not supplied with the printer.
RS232C communication cable
1.Recommended cable length: 3 m
2.Pin connection : below table
Terminal device such P/C ATB printer
D-sub
25 pins
D-sub
9 pins
D-sub
25 pins
Pin
number
Pin
number
Signals
Signals
Pin
number
7 5
GND
GND
7
2 3
TxD
TxD
2
3 2
RxD
RxD
3
5 8
CTS
CTS
5
8 1
DCD
DCD
8
4 7
RTS
RTS
4
20 4 DTR
DTR
20
6 6
DSR
DSR
6
Housing
or pin 1
Housing FG
FG Housing
or pin 1
to ATB Printer
Power cable
1. The cord is specified in VDE 0281, or CENELEC HD21 S2 in Europe,
also specified in UL or CSA in America.
Connector to ATB Printer
Normal voltage 250V-AC - 10A is needed for the cable code in Germany.
Normal voltage 115V-AC - 10A are needed for the cable code in USA.
2. The connector for a device is specified in German standard VDE 0625 or
European standard EN60320
3. The plug is specified in VDE 0620, also CEE IEC884-1
The plug should be selected according to the local standard in the country
of installation.
4. Cable length of 3 m is recommended.
11