– 1 –
S P E C I F I C A T I O N S
TYPE
COOLING
INDOOR UNIT
ABY24AGB-W
OUTDOOR UNIT
AOY24ANA
COOLING CAPACITY
(W)
6,550 - 6,750
POWER SOURCE
(V)
220 - 240
FREQUENCY
(Hz)
50
RUNNING CURRENT
(A)
13.2 -13.4
INPUT
(W)
2,670 - 2,780
EER
(W/W)
2.45 - 2.42
MOISTURE REMOVAL
(
r
/hr)
3.4
AIR CIRCULATION-Hi
(m
3
/hr)
900
ELECTRICAL DATA
COMPRESSOR
DIMENSIONS
TYPE
Hermetic type, Permanent split condenser,
2 pole, Single phase, Induction motor
CODE
2JS438D5AA02
REFRIGERANT
R-22
(g)
1,870
POWER SOURCE
(V)
240
TYPE
MFA-24CTA
INDOOR UNIT
HI-SPEED
(r.p.m.)
1,180
MED-SPEED (r.p.m.)
1,040
LO-SPEED
(r.p.m.)
900
OUTDOOR UNIT
TYPE
MFB-247FB
FAN SPEED
(r.p.m.)
735
INDOOR UNIT
H x W x D
(mm)
199 x 990 x 655
OUTDOOR UNIT
643 x 840 x 336
FAN MOTOR
WEIGHTS
ADDITIONAL REFRIGERANT CHARGE
INDOOR UNIT
GROSS / NET
(kg)
39 / 30
OUTDOOR UNIT
68 / 60
PIPE LENGTH
5 m ( 16 ft. )
7 m ( 23 ft. )
10 m ( 33 ft. )
15 m ( 49 ft. )
20 m ( 66 ft. )
FULL CHARGE AMOUNT
1,870 g (66.0 oz.) 1,902 g (67.1 oz.) 1,950 g (68.8 oz.) 2,030 g (71.6 oz.) 2,110 g (74.4 oz.)
Note : In the case that 5 m are exceeded, when using a connection pipe other than that in the table,
charge additional refrigerant with 16 g (0.56 oz.) / 1 m (3.3 ft.) as the criteria.