MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is 

lost or otherwise unavailable.

*Limited to only when receiver unit is connected.

 CAUTION

Do not press the MANUAL AUTO button with wet hands or pointed ob-

jects, otherwise an electric shock or malfunction may occur.

Starting Operation

Press the MANUAL AUTO button on the operating 

control panel.

The operation can be set in the following setting.

Operating mode

AUTO:

When Auto mode cannot be selected, it will 

operate in the same mode as the other indoor 

unit in the same system. (When other indoor 

unit in the same system doesn’t operate, the air 

conditioner will operate in cooling.)

Fan speed

AUTO

Setting temperature 23 °C

Stopping Operation

Press the MANUAL AUTO button on the operating 

control panel.

OPERATING TIPS

Operation and Performance

About priority state and standby state

 

Multiple indoor units can be connected within the same system. De-

pending on the system, choice of operating mode are limited.

Cooling priority state

When the other indoor units within the same system operate in cooling 

or dry mode, heating can not be selected at the same time.

Heating priority state

When the other indoor units within the same system operate in heating 

mode, cooling and dry mode can not be selected at the same time.

Standby state

The standby state activates when 2 or more indoor units start up at the 

same time in different mode. Any indoor unit other than priority mode 

will wait in standby state until priority mode changes (operation starts 

as soon as priority is switched).

At this time, the OPERATION indicator lamp (green) lights up and the 

TIMER indicator lamp (orange) flashes. (limited to only when receiver 

unit is connected)

Low ambient cooling

 

When the outdoor temperature drops, the outdoor unit’s fans may 

switch to Low Speed, or one of the fans may stop intermittently.

Heating performance

 

Heating mode operates on the heat-pump principle, absorbing heat 

from outdoor air and transferring that heat indoors. As a result, the 

operating performance is reduced as outdoor air temperature drops. 

If you feel that insufficient heating performance is being produced, we 

recommend you use this air conditioner in conjunction with another 

type of heating appliance.

 

Heating mode heat your entire room by recirculating air throughout the 

room, with the result that some time may be required after first starting 

the air conditioner until the room is heated.

Microcomputer-controlled automatic defrosting

 

When using the Heating mode under conditions of low outdoor air 

temperature high humidity, frost may form on the outdoor unit, result-

ing in reduced operating performance. In order to prevent this kind of 

reduced performance, this unit is equipped with a Microcomputer-con-

trolled automatic defrosting function. If frost forms, the air conditioner 

will temporarily stop, and the defrosting circuit will operate briefly (for 

about 4 to 15 minutes).  

During Automatic Defrosting operation, the OPERATION indicator 

lamp (green) will flash (limited to only when receiver unit is connected).

Oil recovery operation

 

Periodically, the oil recovery operation is performed in order to return 

compressor oil to the outdoor unit.  

During oil recovery operation, the OPERATION indicator lamp (green) 

will flash (for about 10 minutes) (limited to only when receiver unit is 

connected).

Temperature and humidity range

 

The temperature and humidity required for operating this product is as 

shown in the following table.

Cooling/Dry Mode

Heating Mode

Outdoor  

temperature

Please refer to the specification of outdoor units.

Indoor  

temperature

About 18 to 32 °C DB

About 10 to 30 °C DB

Indoor humidity

About 80% or less

 

If the air conditioner is operated under higher temperature conditions 

than those listed, the built-in protection circuit may operate to prevent 

internal circuit damage. Also, during Cooling and Dry modes, if the unit 

is used under conditions of lower temperature than those listed above, 

the heat-exchanger may freeze, leading to water leakage and other 

damage.

 

If the unit is used for long periods under high-humidity conditions, 

condensation may form on the surface of the indoor unit, and drip onto 

the floor or other objects underneath.

 

Do not use this unit for any purposes other than the Cooling, Heating, 

Dehumidifying, and air-circulation of rooms in ordinary dwellings.

CLEANING AND CARE

 CAUTION

 

Before cleaning the unit, be sure to stop the unit and disconnect the 

power supply.

 

Do not stand on an unstable platform when cleaning.

 

● When removing and replacing the air filters, be sure not to touch the 

heat exchanger, as personal injury may result.

 

Do not clean the inside of the unit by yourself. To clean the inside, 

always consult authorized service personnel.

 

When cleaning the unit’s body, do not use water hotter than 40 °C, 

harsh abrasive cleansers, or volatile agents like benzene or thinner.

 

● If dirt is allowed to accumulate on the air filter, airflow will be reduced, 

lowering operating efficiency and increasing noise.

 

During periods of normal use, the air filters should be cleaned regu

-

larly.

Cleaning the Air Filter

Cleaning

Cleaning the Air filter

Remove dust with a vacuum cleaner or by washing. After washing, be 

sure to allow it to dry thoroughly in a shady place before reinstalling.

When not using for an extended period

Leave the breaker on for at least 12 hours before starting operation when 

it is to be used again.

9374343430_OM.indb   2

07/02/2019   14:59:47

Summary of Contents for AirStage ARXA024GLEH

Page 1: ...iano MANUALE DI ISTRUZIONI UNITÀ INTERNA tipo a condotto Conservare questo manuale per consultazione futura Ελληνικά Português ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Τύπος αγωγού Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR Tipo de tubagem Guarde este manual para consulta futura Русский Türkçe РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ Короб Со...

Page 2: ...n the unit directly or wash the unit with them Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy pressure to radiator fins Do not use inflammable gases near the air conditi...

Page 3: ...result ing in reduced operating performance In order to prevent this kind of reduced performance this unit is equipped with a Microcomputer con trolled automatic defrosting function If frost forms the air conditioner will temporarily stop and the defrosting circuit will operate briefly for about 4 to 15 minutes During Automatic Defrosting operation the OPERATION indicator lamp green will flash lim...

Page 4: ...ling sound may be heard occasionally This sound is produced by the Automatic Defrosting operation See page 2 Smells Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Fog comes out of the indoor unit During Cooling operation a thin mist may be seen emitted from the indoor unit This results from...

Page 5: ...4 240 CURRENT A 0 60 0 69 1 18 1 43 SOUND PRESSURE LEVEL HIGH dB A 31 34 37 41 MED HIGH dB A 29 33 36 40 MED dB A 27 32 35 38 MED LOW dB A 26 31 35 38 LOW dB A 24 30 34 37 QUIET dB A 23 29 33 36 DIMENSIONS WEIGHT HEIGHT mm 270 WIDTH mm 1 135 DEPTH mm 700 WEIGHT kg 36 40 Acoustic Noise Information The maximum sound pressure level is less than 70 dB A for both indoor unit and outdoor unit According ...

Page 6: ...9374343430_OM indb 6 07 02 2019 14 59 54 ...