background image

En-3

Oil recovery operation

 

Periodically, the oil recovery operation is performed in order to return 
compressor oil to the outdoor unit. During oil recovery operation, the 
OPERATION indicator lamp (green) will 

fl

 ash (for about 10 minutes).

Temperature and humidity range

 

The temperature and humidity required for operating this product is as 
shown in the following table.

Cooling/Dry Mode

Heating Mode

Outdoor 
temperature

Please refer to the speci

fi

 cation of outdoor units.

Indoor 
temperature

18 to 32 °C DB

10 to 30 °C DB

Indoor humidity

About 80% or less

 

If the air conditioner is operated under higher temperature conditions 
than those listed, the built-in protection circuit may operate to prevent 
internal circuit damage. Also, during Cooling and Dry modes, if the unit 
is used under conditions of lower temperature than those listed above, 
the heat-exchanger may freeze, leading to water leakage and other 
damage.

 

If the unit is used for long periods under high-humidity conditions, 
condensation may form on the surface of the indoor unit, and drip onto 
the 

fl

 oor or other objects underneath.

 

Do not use this unit for any purposes other than the Cooling, Heating, 
Dehumidifying, and air-circulation of rooms in ordinary dwellings.

CLEANING AND CARE

 CAUTION

 

Before cleaning the unit, be sure to stop the unit and disconnect the 
power supply.

 

Do not stand on an unstable platform when cleaning.

 

When removing and replacing the air 

fi

 lters, be sure not to touch the 

heat exchanger, as personal injury may result.

 

Be sure the intake grille is installed securely.

 

Do not clean the inside of the unit by yourself. To clean the inside, 
always consult authorized service personnel.

 

When cleaning the unit’s body, do not use water hotter than 40 °C, 
harsh abrasive cleansers, or volatile agents like benzene or thinner.

 

Do not remove any part from the unit except for the 

fi

 lter.

 

If dirt is allowed to accumulate on the Air Filter, air

fl

 ow will be reduced, 

lowering operating ef

fi

 ciency and increasing noise.

 

During periods of normal use, the air 

fi

 lters should be cleaned every 2 

months.

Cleaning the Air Filter

When the 

fi

 lter lamp lights on, remove and clean the 

fi

 lter.

1. Push the intake grille push-buttons (two places) 

and open the intake grille.

2. Pull out the 

fi

 lter from the intake grille.

1.

2.

Situations in which the sensor will detect no people in the room, 
even when there is someone there

 

When the temperature is high and the difference with between people’s 
body temperature is small. (Such as during the summer when the 
temperature is 30°C or higher.)

 

When there is someone in the room, but they do not move for a long 
period of time.

 

When someone is hidden behind a sofa, other furniture, glass, or in 
similar situations.

 

When someone is wearing extremely thick clothing and has their back 
facing the sensor.

Situations in which the sensor will incorrectly detect people in the 
room, even when there is no one there

 

When there is a dog or a cat moving around in the room.

 

When the wind is making curtains or plants move.

 

When there are heating units, humidi

fi

 ers, or electric appliances such 

as oscillating electric fans operating.

OPERATING TIPS

Operation and Performance

About priority state and standby state

 

Multiple indoor units can be connected within the same system. De-
pending on the system, choice of operating mode are limited.

Cooling priority state:

When the other indoor units within the same system operate in cooling 
or dry mode, heating can not be selected at the same time.

Heating priority state:

When the other indoor units within the same system operate in heating 
mode, cooling and dry mode can not be selected at the same time.

Standby state:

The standby state activates when 2 or more indoor units start up at the 
same time in different mode. Any indoor unit other than priority mode 
will wait in standby state until priority mode changes (operation starts 
as soon as priority is switched).
At this time, the OPERATION indicator lamp (green) lights up and the 
TIMER indicator lamp (orange) 

fl

 ashes.

Low ambient cooling

 

When the outdoor temperature drops, the outdoor unit’s fans may 
switch to Low Speed, or one of the fans may stop intermittently.

Heating performance

 

Heating mode operates on the heat-pump principle, absorbing heat 
from outdoor air and transferring that heat indoors. As a result, the 
operating performance is reduced as outdoor air temperature drops. 
If you feel that insuf

fi

 cient heating performance is being produced, we 

recommend you use this air conditioner in conjunction with another 
type of heating appliance.

 

Heating mode heat your entire room by recirculating air throughout the 
room, with the result that some time may be required after 

fi

 rst starting 

the air conditioner until the room is heated.

Microcomputer-controlled automatic defrosting

 

When using the Heating mode under conditions of low outdoor air 
temperature high humidity, frost may form on the outdoor unit, result-
ing in reduced operating performance. In order to prevent this kind of 
reduced performance, this unit is equipped with a Microcomputer-con-
trolled automatic defrosting function. If frost forms, the air conditioner 
will temporarily stop, and the defrosting circuit will operate brie

fl

 y (for 

about 4 to 15 minutes). 
During Automatic Defrosting operation, the OPERATION indicator 
lamp (green) will 

fl

 ash.

9369313332_OM.indb   3

9369313332_OM.indb   3

12/19/2018   2:47:17 PM

12/19/2018   2:47:17 PM

Summary of Contents for Airstage AUXM018GLEH

Page 1: ...L DE FUNCIONAMENTO UNIDADE INTERIOR Tipo cassete Guarde este manual para consulta futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ кассетного типа Сохраните данное руководство для последующего использования KULLANIM KILAVUZU İÇ ÜNİTE Kaset tipi Bu kılavuzu ileride başvurmak üzere saklayın MODE D EMPLOI UNITÉ INTÉRIEURE Type cassette Conservez ce manuel pour pour toute référence ultérieure Deut...

Page 2: ...and for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy pressure to radiator fins Do not use inflammable gases near the air conditioner Do not touch the piping during operation Ensure that any electronic equipment is at least 1 m away from either the indoor or outdoor units This appliance is not intended for use by perso...

Page 3: ... done in the remote control ler of the following UTY RNR Z wired remote controller Refer to the operating manual of the remote controller HUMAN SENSOR Optional About the human sensor The Human sensor detects whether there are people in the room by looking for movement by people in the room Limited to only when Human censor kit is attached Setting of Human sensor can be done in the remote controlle...

Page 4: ...ove for a long period of time When someone is hidden behind a sofa other furniture glass or in similar situations When someone is wearing extremely thick clothing and has their back facing the sensor Situations in which the sensor will incorrectly detect people in the room even when there is no one there When there is a dog or a cat moving around in the room When the wind is making curtains or pla...

Page 5: ...eed Flashing lamps The OPERATION indicator lamp green flashes An oil recovery operation is being performed See page 2 The OPERATION indicator lamp green flashes An automatic defrosting operation is being per formed See page 2 The OPERATION indicator lamp green and TIMER indicator lamp orange are flashing alternately It has recovered from a power outage The OPERATION indicator lamp green and TIMER ...

Page 6: ...3 8 0 BTU h 21 500 27 300 34 100 21 500 27 300 INPUT POWER W 20 25 49 40 40 CURRENT A 0 20 0 24 0 41 0 34 0 34 SOUND PRESSURE LEVEL HIGH dB A 33 35 40 38 38 MED HIGH dB A 32 33 36 37 37 MED dB A 31 32 34 36 36 MED LOW dB A 30 31 32 35 35 LOW dB A 29 30 31 34 34 QUIET dB A 28 28 28 33 33 DIMENSIONS WEIGHT HEIGHT mm 246 288 WIDTH mm 840 DEPTH mm 840 WEIGHT kg 24 24 5 26 5 MODEL AUXK 030GLEH AUXK 034...

Page 7: ...9369313332_OM indb 6 9369313332_OM indb 6 12 19 2018 2 47 18 PM 12 19 2018 2 47 18 PM ...

Page 8: ...9369313332_OM_AR indd 7 9369313332_OM_AR indd 7 12 19 2018 2 37 17 PM 12 19 2018 2 37 17 PM ...