En-5
●
In the case of Cooling operation, are there heating apparatus and com-
puters inside the room, or are there too many people in the room?
●
Is the fan speed set to low?
●
Is the Auto saving operation of the Human sensor setting active? (See
page 2)
Set the temperature lower than the room temperature and use it:
●
Temperature does not fall down well. Temperature may not fall down
depending on the room conditions. (While high humidity or the room
temperature is high.) (See page 3)
In the following situations stop operation immediately
and get in touch with authorized service personnel.
●
The problem cannot be solved even when the troubleshooting checks
have been performed.
●
The FILTER indicator lamp (red) is
fl
ashing very fast.
●
The wired remote controller or simple remote controller indicate Er
(when connected).
●
It has burning smell.
SPECIFICATIONS
MODEL
AUXN009GLAH
AUXN012GLAH
AUXN014GLAH
POWER SOURCE
220-240V ~ 50Hz, 230V ~ 60Hz
AVAILABLE VOLT-
AGE RANGE
198 to 264 V (50Hz) , 198 to 253 V (60Hz)
COOLING
CAPACITY
[kW]
2.8
3.6
4.5
[BTU/h]
9,600
12,300
15,400
HEATING
CAPACITY
[kW]
3.2
4.0
5.0
[BTU/h]
10,900
13,600
17,100
INPUT
POWER
[W]
20
20
20
CURRENT
[A]
0.20
0.20
0.20
SOUND PRESSURE LEVEL
HIGH
dB [A]
33
33
33
MED - HIGH dB [A]
32
32
32
MED
dB [A]
31
31
31
MED - LOW dB [A]
30
30
30
LOW
dB [A]
29
29
29
QUIET
dB [A]
28
28
28
DIMENSIONS & WEIGHT
HEIGHT
[mm]
246
WIDTH
[mm]
840
DEPTH
[mm]
840
WEIGHT
[kg]
24.5
●
Acoustic Noise Information:
The maximum sound pressure level is less than 70 dB (A) for both
indoor unit and outdoor unit. According IEC 704-1 and ISO 3744.
●
This product contains
fl
uorinated greenhouse gases.
9369313318-01_OM_L9.indb 5
9369313318-01_OM_L9.indb 5
6/6/2018 13:15:27
6/6/2018 13:15:27