En-2

PREPARATORY OPERATION

Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

Set the current day and time

Press for 3 seconds.

Select the number that corresponds to
the current day indicated by a code from
1 to 7.

1

2

Press repeatedly to adjust the current
time in 1-minute increments. Press con-
tinuously to adjust the current time in 10-
minute increments.

Press again to end.

3

4

Day code

1

2

3

4

5

6

7

Day of the

Mon Tue Wed Thu Fri Sat Sun

week

To start/stop operation

Start time: Operation lamp will light up.
Stop time: Operation lamp will go out.

Operation mode setting

→ 

 AUTO

 →

 

 COOL

 

 DRY

 →

 

 FAN

 →

 

 HEAT

NOTES

To set the operation mode

(1)

• Always use the remote controller’s AIRFLOW DIRECTION button.

Attempting to move the air direction louvers manually could re-
sult in improper operation; in this case, stop operation and re-
start.
The flaps should begin to operate properly again.

• During use of the Cooling mode, do not set the VERTICAL air

direction flap in the 

4

 position for long time, since water vapor

may condense near the outlet port and drops of water may drip
from the air conditioner.

(2)

• The range of swing is relative to the currently set airflow direc-

tion.

• The SWING operation may stop temporarily when the air condi-

tioner’s fan is not operating, or when operating at very low speeds.

<Vertical airflow swing operation>
Airflow direction

Range of swing

1

1

 to 

3

2

2

 to 

4

3

2

 to 

4

4

1

 to 

4

 (All range)

<Horizontal airflow swing operation>
Airflow direction

Range of swing

1

1

 to 

5

 (All range)

2

1

 to 

3

3

2

 to 

4

4

3

 to 

5

5

1

 to 

5

 (All range)

Fan speed setting

Room temperature setting

Vertical air direction adjustment (1)(2) (Swing operation)

Horizontal air direction adjustment (2) (Swing operation)

* Press the START/STOP button to start the air conditioner,

and then proceed as follows.

To set the swing operation, press the VERTICAL
SWING button for more than 2 seconds. (Stop
the setting by pressing for more than 2 seconds
again.)

To set the swing operation, press the HORIZON-
TAL SWING button for more than 2 seconds.
(Stop the setting by pressing for more than 2
seconds again.)

Temperature setting range:
AUTO ....................................................... 18 to 30 

°

C

Heating .................................................... 16 to 30 

°

C

Cooling/Dry ............................................. 18 to 30 

°

C

1

 

2

 

3

 

4

1

 

2

 

3

 

4

 

5

→ 

 AUTO 

 

HIGH

MED

LOW

Energy save setting

Anti freeze setting

Stop the “ENERGY SAVE” setting by pressing
the ENERGY SAVE button again.

Press at the same time for more than 3 seconds.
Stop the “ANTI FREEZE” setting by pressing

 at the same time for more than 3 sec-

onds again.

* Press the START/STOP button to stop the air conditioner,

and then proceed as follows.

1

2

3

4

1 2

3

4 5

OPERATION

Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

* Press the START/STOP button to start the air conditioner,

and then proceed as follows.

Summary of Contents for Airstage UTB- LB Series

Page 1: ...CONDITIONER OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES Remote Control Unit UTB LB REMOTE CONTROLLER WIRED TYPE TM English Deutsch Français Español Italiano EλληvIkά Русский Português ...

Page 2: ...which if improperly performed might possibly result in personal harm to the user or damage to property This mark indicates procedures which if improperly performed might lead to the death or serious injury of the user DANGER Do not attempt to install this controller by yourself This controller contains no user serviceable parts Al ways consult authorized service personnel for repairs When moving c...

Page 3: ...s not operating or when operating at very low speeds Vertical airflow swing operation Airflow direction Range of swing 1 1 to 3 2 2 to 4 3 2 to 4 4 1 to 4 All range Horizontal airflow swing operation Airflow direction Range of swing 1 1 to 5 All range 2 1 to 3 3 2 to 4 4 3 to 5 5 1 to 5 All range Fan speed setting Room temperature setting Vertical air direction adjustment 1 2 Swing operation Horiz...

Page 4: ...seconds The WEEKLY 1 ON time starts flashing To set the WEEKLY timer For information concerning the WEEKLY TIMER function refer to p 7 OPERATING TIPS Press the START STOP button to stop the air conditioner and then proceed as follows 4 Set the WEEKLY 1 ON time Press repeatedly to adjust the time in 5 minute increments Press continuously to adjust the time in 10 minute incre ments 5 The day display...

Page 5: ...sure to set the ON time first then the OFF time If either the ON time or the OFF time is not set correctly the timer will not operate properly The WEEKLY 2 settings cannot be set earlier than the WEEKLY 1 settings The WEEKLY 1 and WEEKLY 2 time spans cannot overlap 2 The earliest OFF time you can set is 5 minutes after the ON time The latest OFF time is 23 55 on the subsequent day 3 You do not nee...

Page 6: ...AY OFF function refer to p 7 OPERATING TIPS Press the START STOP button to stop the air conditioner and then proceed as follows 1 Select 2 Select the number that corresponds to the selected day indicated by a code from 1 to 7 3 The DAY OFF caption appears on the display Stop the DAY OFF setting by press ing the DAY OFF button again Perform steps 1to 3in To set the WEEKLY timer P 3 Select the day t...

Page 7: ...re is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During defrost ing the heating mode will be temporarily interrupted DEFROST will be shown on the remote controller display Fan speed When set to AUTO FAN speed Heating The fan will operate at very low speed when the...

Page 8: ...occurred TROUBLESHOOTING Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle 1 If the operation lamp is on press the START STOP button to turn it off 2 Press SET TIME and TEMP DAY but tons at the same time for more than 3 seconds to start the self diagnosis check Error code Remote controller address 3 Press the SET TIME and TEMP DAY buttons at the same time for mo...

Page 9: ...eration if the room temperature rises above the set temperature the outdoor unit will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further set the set the temperature for a higher setting During Heating operation the unit will temporarily stop opera tion between 2 and 16 minutes as the Automatic Defrosting mode operates During Automatic Defrosting operat...

Reviews: