"MODE/ EXIT" button
short press
"ENTER" button
short press
It changes if the
"SELECT" buttonis
short pressed
"ENTER" button
short press
Select the History Number
Return to the Monitor Mode
example) Normal display (Cooling operation)
Change to the Error History Mode from the Mode Selection Display
Select the Error History Number
Check the detail of the Error History
00
01
02
09
Select the History Number
example) Error Code : E711
Mode selection display
The newest History Number and
Error Code are displayed by the 2 digits
: Light off
: Flashing
: Lighting
The History Number changes sequentially
from "00" to "09" by the "SELECT" button
End of the Error History mode
Mode Selection Display
Monitor Mode
Select the
Error History Number
Display details
of the
Error History
ERROR HISTORY MODE
3
2
4
1
4
3
2
1
Error History Number : [00]Error Code : [71]
4-2-8 ERROR HISTORY MODE
[Forward]
[Forward]
"SELECT" button
short press
LED101
LED104
POWER
MODE
ERROR
(GREEN)
LED102
(RED)
LED105
"ENTER" button
short press
It changes if the
"SELECT" button
is short pressed
[Forward]
Error History Number : [01]
Error Code : [- -]
There is no Error History yet,
in the object History Number
(Newest)
(Oldest)
Detail of Error Code is displayed by the 3 digits
If there is no Error History,
detail of Error Code is displayed as above
When the abnormality occurred, the Outdoor unit memorizes the history of error codes up to 10
and it can be displayed on 7 segments LED.
It is an effective means to examine abnormality that occurred in the past.
*The error history can be cleared by setting to F3-30.
Refer to the following for the procedure.
LED105
04-09
Summary of Contents for Airstage UTP-RU01AH
Page 1: ...SERVICE MANUAL 208 230V 60Hz ...
Page 5: ...1 TEST RUN ...
Page 6: ......
Page 34: ...2 OUTDOOR UNIT OPERATION CONTROL ...
Page 59: ...3 INDOOR UNIT OPERATION ...
Page 60: ......
Page 82: ......
Page 83: ...4 TROUBLE SHOOTING ...
Page 84: ......
Page 186: ...04 96 0 24 AOUA120 208 230 AOUA72 90 0 19 RED WHITE BLACK U V W ...
Page 208: ...5 APPENDING DATA UNIT ...
Page 209: ......
Page 215: ...CASSETTE TYPE MODELS AUUB18TLAV AUUB24TLAV AUUB30TLAV AUUB36TLAV 05 06 ...
Page 217: ...MEDIUM STATIC PRESSURE DUCT TYPE MODEL ARUM24TLAV 05 08 MODEL ARUM30TLAV ARUM36TLAV ...
Page 218: ...HIGH STATIC PRESSURE DUCT TYPE MODELS ARUH36TLAV ARUH48TLAV ARUH60TLAV 05 09 ...
Page 219: ...FLOOR CEILING TYPE MODELS ABUA12TLAV ABUA14TLAV ABUA18TLAV ABUA24TLAV 05 10 ...
Page 220: ...CEILING TYPE MODELS ABUA30TLAV ABUA36TLAV INDOOR UNITS INDOOR UNITS 05 11 ...
Page 221: ...WALL MOUNTED TYPE MODELS ASUA7TLAV ASUA9TLAV ASUA12TLAV ASUA14TLAV 05 12 ...
Page 222: ...MODELS ASUB18TLAV ASUB24TLAV 05 13 ...
Page 224: ...MODEL UTP RU01AH MODEL UTP RU01BH 5 2 3 RB Unit 05 15 ...
Page 225: ...MODEL UTP RU01CH 05 16 ...
Page 226: ...MODEL UTP RU04BH 05 17 ...
Page 227: ...MODELS AAUA48TLAV 5 2 4 Outdoor Air Unit 05 18 MODELS AAUA72TLAV ...
Page 228: ...MODELS AAUA96TLAV 05 19 ...
Page 230: ...6 DISASSEMBLY PROCESS ...
Page 245: ......