INSTALLATION MANUAL

安装说明书

MANUEL D’INSTALLATION

MANUAL DE INSTALACIÓN

MANUAL DE INSTALAÇÃO

For authorized service personnel only.

只适用于专业维修人员

Uniquement réservé aux techniciens agréés.

Sólo para personal de mantenimiento autorizado.

Apenas para técnicos de assistência autorizados.

PART NO. 9708436029

NETWORK CONVERTOR

CONVERSOR DE REDE

CONVERTIDOR DE RED

ADAPTATEUR RESEAU

网络转换器

UTY-VLGX

Summary of Contents for Airstage UTY-VLGX

Page 1: ...ANUAL DE INSTALAÇÃO For authorized service personnel only 只适用于专业维修人员 Uniquement réservé aux techniciens agréés Sólo para personal de mantenimiento autorizado Apenas para técnicos de assistência autorizados PART NO 9708436029 NETWORK CONVERTOR CONVERSOR DE REDE CONVERTIDOR DE RED ADAPTATEUR RESEAU 网络转换器 UTY VLGX ...

Page 2: ...such as paint thinner or gasoline If gas leaks and settles around the unit it can cause a fire Do not use the unit for special purposes such as storing food raising animals growing plants or preserving pre cision devices or art objects It can degrade the quality of the preserved or stored objects Install the unit in a well ventilated place avoiding rains and direct sunlight Do not operate this uni...

Page 3: ...d the transmis sion cable together with or parallel to the power supply cable of the indoor and outdoor units It may cause er roneous operation When performing wiring work be careful not to damage the cable or injure yourself Also connect the connectors securely Loose connectors will cause trouble heating fire or electric shock Install the indoor and outdoor units power supply cable transmission c...

Page 4: ...cable The shield metal should be earthed grounded Do not forget to earth ground the Network Convertor Install the disconnect switch to the easily accessible loca tion Install the fuse 3A to the L line of power supply cable Confirm the name of each unit and name of each terminal block of the unit and connect the wiring in accordance with the directions given in the manual so that there is no incorr...

Page 5: ...arth Ground Cable Binder Binder Lock nut Cut for Others Remove the 4 screws M4 6 mm and then remove the cover Open the knockout hole and then install dust proof bushing If small animals such as insects and dust enter this unit a short circuit may be caused Make a hole in the center of the dust proof bush ing with the Phillips head screwdriver Pass the power supply cable through the hole of dust pr...

Page 6: ...l for Network Convertor D14 D14 Binding and Commissioning is not executed Normal Mode Ready for operation Others Refer to 11 LED DISPLAY D19 for more detail Network Convertor does not operate during initialization If an error occurs the D9 or D14 LED lights or flashes or the error code is displayed on the right side of the D19 LED display ADDRESS SETTING 888 Setting up more than 1 Network Converto...

Page 7: ...ock in the Network Con vertor and the Network Convertor if register the changed XIF file in according to the Tool for Network Convertor Important Network Convertor will not operate if VRF network system address Indoor Outdoor units ad dress allocation information are not registered to Net work Convertor XIF data information and VRF network system address allocation information must not be same Bin...