SAFETY PRECAUTIONS

11 

The “SAFETY PRECAUTIONS” indicated in 

 

this manual 

contain important information pertaining to your safety. 

Be sure to observe them.

Request the user to keep 

 

this manual on hand for future 

use, such as for relocating or repairing the unit.

WARNING

This mark indicates procedures which, 

if improperly performed, might lead to 

the death or serious injury of the user.

Perform electrical work by an authorized service person-

nel in accordance with this manual and the electrical 

wiring regulations or implementation regulations of the 

country. Also do not install this unit by yourself. Improper 

electric work will cause electric shock or a fire.

Perform installation work in accordance with this manual. 

Request an authorized service personnel to perform in-

stallation work. Do not install this unit by yourself. Improp-

er installation will cause injury, electric shock, fire, etc.

In the event of a malfunction (burning smell, etc.), imme-

diately stop operation, turn off the electrical breaker, and 

consult authorized service personnel.

Install a leakage circuit breaker to power supply cable 

in accordance with the related laws and regulations and 

electric company standards.

Use a power source exclusively for this unit. Never share 

the power source with other electrical equipment. Doing 

so will cause fire and electric shock.

Do not install the unit in the following areas:

Do not install the unit near a source of heat, steam, or 

 

flammable gas. 

Area filled with mineral oil or containing a large amount 

 

of splashed oil or steam, such as a kitchen. It will dete-

riorate plastic parts, causing the parts to fail or the unit to 

leak water.

Area that generates substances that adversely affect the 

 

equipment, such as sulfuric gas, chlorine gas, acid, or 

alkali. It will cause the copper pipes and brazed joints to 

corrode, which can cause refrigerant leakage.

Area containing equipment that generates electromag-

 

netic interference. It will cause the control system to 

malfunction, preventing the unit from operating normally.

Area that can cause combustible gas to leak, contains 

 

suspended carbon fibers or flammable dust, or volatile 

inflammables such as paint thinner or gasoline. If gas 

leaks and settles around the unit, it can cause a fire.

Do not use the unit for special purposes, such as storing 

 

food, raising animals, growing plants, or preserving pre-

cision devices or art objects. It can degrade the quality 

of the preserved or stored objects.

Install the unit in a well-ventilated place avoiding rains 

 

and direct sunlight.

Do not operate this unit when your hands are wet. Touch-

ing the unit with wet hands will cause an electric shock.
If children may approach the unit, take preventive mea-

sures so that they cannot reach the unit.

CAUTION

This mark indicates procedures which, 

if improperly performed, might possibly 

result in personal harm to the user or 

damage to property.

Pay abundant care when transporting this unit because it 

is a precision device. Improper transportation will cause 

trouble.
Do not touch the switches with sharp objects. Doing so will 

cause injury, trouble, or electric shock.
Do not expose this unit directly to water. Doing so will 

cause trouble, electric shock, or heating.
Do not set vessels containing a liquid on this unit. Doing 

so will cause heating, fire, or electric shock.

Dispose of the packing materials safely. Tear and dispose 

of the plastic packing bags so that children cannot play 

with them. There is the danger of suffocation if children 

play with the original plastic bags.
Do not insert articles into the slit parts of this unit. Doing 

so will cause trouble, heating, or electric shock.

MAIN UNIT AND ACCESSORIES

21 

Important:  Please print manual other than the installation 

manual from attached CD-ROM before starting 

the installation work.

The following installation parts are supplied. Use them as 

required.

Name and Shape

Q’ty

Application

Network convertor

1

Main unit

Installation manual

1

This manual

Binder

3

For mounting the power

supply cable and

transmission cable.   

INSTALLATION MANUAL

PART NO. 9708436029

NETWORK CONVERTOR

Contents

1.  SAFETY PRECAUTIONS  ………………………………1
2.  MAIN UNIT AND ACCESSORIES  ……………………1
3.  ELECTRICAL REQUIREMENT …………………………2
4.  SELECTING AN INSTALLATION LOCATION  ………2

4. 1.  Dimensions  ………………………………………2

5.  WIRING  ……………………………………………………2

5. 1.  Wiring method  ……………………………………3

6.  INSTALLING THE NETWORK CONVERTOR  ………4

6. 1.  Connecting the power supply cable ……………4

6. 2.  Connecting the transmission cables ……………4

7.  TURNING ON THE POWER ……………………………5
8.  ADDRESS SETTING  ……………………………………5
9.  INITIAL SETTING (SOFTWARE) ………………………6
10. BINDING & COMMISSIONING (NOTICE)  ……………6
11.  LED DISPLAY (D19) ………………………………………6

Summary of Contents for Airstage UTY-VLGX

Page 1: ...ANUAL DE INSTALAÇÃO For authorized service personnel only 只适用于专业维修人员 Uniquement réservé aux techniciens agréés Sólo para personal de mantenimiento autorizado Apenas para técnicos de assistência autorizados PART NO 9708436029 NETWORK CONVERTOR CONVERSOR DE REDE CONVERTIDOR DE RED ADAPTATEUR RESEAU 网络转换器 UTY VLGX ...

Page 2: ...such as paint thinner or gasoline If gas leaks and settles around the unit it can cause a fire Do not use the unit for special purposes such as storing food raising animals growing plants or preserving pre cision devices or art objects It can degrade the quality of the preserved or stored objects Install the unit in a well ventilated place avoiding rains and direct sunlight Do not operate this uni...

Page 3: ...d the transmis sion cable together with or parallel to the power supply cable of the indoor and outdoor units It may cause er roneous operation When performing wiring work be careful not to damage the cable or injure yourself Also connect the connectors securely Loose connectors will cause trouble heating fire or electric shock Install the indoor and outdoor units power supply cable transmission c...

Page 4: ...cable The shield metal should be earthed grounded Do not forget to earth ground the Network Convertor Install the disconnect switch to the easily accessible loca tion Install the fuse 3A to the L line of power supply cable Confirm the name of each unit and name of each terminal block of the unit and connect the wiring in accordance with the directions given in the manual so that there is no incorr...

Page 5: ...arth Ground Cable Binder Binder Lock nut Cut for Others Remove the 4 screws M4 6 mm and then remove the cover Open the knockout hole and then install dust proof bushing If small animals such as insects and dust enter this unit a short circuit may be caused Make a hole in the center of the dust proof bush ing with the Phillips head screwdriver Pass the power supply cable through the hole of dust pr...

Page 6: ...l for Network Convertor D14 D14 Binding and Commissioning is not executed Normal Mode Ready for operation Others Refer to 11 LED DISPLAY D19 for more detail Network Convertor does not operate during initialization If an error occurs the D9 or D14 LED lights or flashes or the error code is displayed on the right side of the D19 LED display ADDRESS SETTING 888 Setting up more than 1 Network Converto...

Page 7: ...ock in the Network Con vertor and the Network Convertor if register the changed XIF file in according to the Tool for Network Convertor Important Network Convertor will not operate if VRF network system address Indoor Outdoor units ad dress allocation information are not registered to Net work Convertor XIF data information and VRF network system address allocation information must not be same Bin...