- (02 - 16) -
O
U
TD
O
O
R U
N
IT
AO
G
07-
14
LE
O
U
TD
O
O
R U
N
IT
AO
G
07-
14
LE
ELECTRIC CHARACTERISTICS
9.
Model name
AO
G07LE AO
G09LE AO
G12LE
AO
G14LE
Power supply
Voltage
V
230 ~
Frequency
Hz
50
*1) Max operating current
A
7.5
7.5
9.0
10.5
Starting Current
A
3.5
3.8
4.7
6.0
*2) Wiring Spec.:
Main Fuse (Circuit breaker)
Current
A
20
Power Cable
mm
2
1.5
*3) Limited wiring length :
m
21
*1) The maximum current is the total current of indoor unit and outdoor unit.
*2) Wiring Spec.:
Selected Sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
*3) Limited wiring length :
This is the wiring length in case voltage descent is less than 2%.
When the wiring length becomes long, please select the wiring of a more larger diameter.