81
8.1.3 Switching the SE server off
The following hardware components must be switched off in the specified order.
1. Switch off the optional Application Units
Before an Application Unit is switched off, the power-on indicator lights up green.
>
Terminate the customer applications and the operating system properly.
The Application Unit is switched off automatically and enters standby mode.
The status indicator lights up orange. Check this before continuing.
Alternatively, as the administrator or AU administrator you can switch the Application Unit off using the SE
Manager (menu
,
tab,
symbol), see the “Operation and Administration”
Hardware
->
Units Units
Power off
Further Application Units are switched off in the same way.
2. Switch off the Server Unit
>
As the administrator, BS2000 administrator or a privileged operator, switch off the Server Unit using the SE
Manager (menu
,
tab,
symbol), see the “Operation and Administration”
Hardware
->
Units Units
Power off
When the Server Unit is switched off, the BS2000 system is shut down properly taking into account the
remaining runtime specified.
Before the Server Unit is switched off, the power-on indicator lights up green, and after it has been switched
off, it lights up orange. Check this before continuing.
Further Server Units are switched off in the same way.
CAUTION!
This does not disconnect the hardware components completely from the power source (POWER STAND-
BY). To cut the entire system off from the power source, you must must disconnect the power distribution
units from the power source.
Notify Customer Support.
!
If the operating system does not automatically switch off the Application Unit, hold the On/Off switch
down for at least four seconds.
i
The controls, indicators and further on/off options for the AU are described in the "Additive Components"
i
The controls and indicators of the Server Unit are described in the "Server Unit x86" Operating Manual [ ].
i