Table 3.35 Brightness
Value
00h
01h
|
80h
|
FFh
Brightness
Default (same to 80h)
Brightest
Normal
Darkest
Value
00h
01h
|
80h
|
FFh
Threshold
Default (same to 80h)
Dynamic Threshold or Simplified Dynamic Threshold
Brightest
Normal
Darkest
Contrast:
0 to 255
The contrast field specifies the level of contrast used to scan the
object. Avalue of zero specifies default contrast or automatic contrast
if it is supported. Any other value indicates a relative contrast setting
with 255 being the highest setting, one being the lowest setting, and
128 being the nominal setting.
Threshold:
0 to 255
The threshold field specifies the threshold at which scan data is
converted tobinary data. A value of zero specifies the default
threshold at automatic threshold control if it is supported. Any other
value indicates a relative threshold setting with 255 being the highest
setting, one being the lowest setting, and 128 being the nominal
setting.The threshold effects for Line Art image.
Table 3.36 Threshold
#03.pm5
98.2.22, 1:32 PM
61
Summary of Contents for C150-E049-02EN
Page 1: ...M3099GX GH IMAGE SCANNER OEM MANUAL C150 E049 02EN 00 1 Cover pm5 98 2 22 1 13 PM 1 ...
Page 2: ...M3099GX GH IMAGE SCANNER OEM MANUAL 00 1 Cover pm5 98 2 22 1 13 PM 2 ...
Page 3: ... 00 1 Cover pm5 98 2 22 1 13 PM 3 ...
Page 157: ...3 124 M3099GX GH OEM Manual 03 pm5 98 2 22 1 34 PM 124 ...
Page 185: ...5 6 M3099GX GH OEM Manual 05 Chapter 5 98 2 22 1 51 PM 6 ...
Page 205: ...8 10 M3099GX GH OEM Manual 08 Chapter 8 98 2 22 1 53 PM 10 ...
Page 225: ...M3099GX GH OEM Manual B 14 A 3 Appendix B 98 2 22 2 42 PM 14 ...