Rack mounting (optional)
Rack mounting (optional)
Due to its weight and external dimensions, at least two persons are required
to install the device in a rack, for safety reasons.
Do NOT use the QRLs (Quick Release Levers) on the front panel
to lift the device into the rack.
When connecting and disconnecting the cables, also follow the instructions in the
"Important Information" chapter of the Operating Manual for the particular rack. The
Operating Manual is supplied together with the rack when it is delivered.
When installing the rack, make sure that the anti-tilt bracket is properly
fi
tted.
A maximum of one unit at a time may be removed from the rack, even if
the anti-tilt bracket is mounted. If several units are pulled out of the rack
simultaneously, there is a danger of the rack tipping over. Please observe the
safety notes for the rack and the corresponding warning label.
For EMEA only: The mains connection of the rack must be carried out
by an authorised professional (electrician).
If the device is integrated in an installation supplied with power by an industrial supply
network with a Type IEC 309 connection plug, the fusing of the power supply network
must meet the requirements for non-industrial power supply networks for plug type A.
Fujitsu rack systems
The following Fujitsu rack systems support the installation of CELSIUS workstations:
•
PRIMECENTER Rack
•
PRIMECENTER M1 Rack
•
DataCenter Rack
•
19 inch Standard Rack
•
19 inch Slimline Rack (for Japan)
For information on how to mount the device in the rack, see the mounting instructions provided with
the rack installation kit. Additional information is contained in the manual for the rack system.
Online documentation on rack installation can be found at:
"http://manuals.ts.fujitsu.com/index.php?id=5406-5605-5606"
In order to satisfy the ventilation concept and provide suf
fi
cient air to the devices, all
the unoccupied areas in the rack must be closed off with dummy covers.
The mains connection is made using the existing power strips in the particular rack (for EMEA).
Fujitsu rack systems have the following characteristics:
•
Rail systems that can be mounted without tools
•
Mounting systems with the facility for length adjustment, which guarantees
alignment to various rack depths.
Asymmetric PRIMECENTER and DataCenter racks offer enhanced cable
management in the side area of the rack.
Fujitsu
23