Table 47
Node shutdown
Probable Cause
Severity
Corrective Action
Node is shut down
Note:
Reports alarm only
Major
Take no action
Table 48
Sync status changes
Probable Cause
Severity
Corrective Action
Sync failed
Sync not connected
Out-of-sync
Desynchronization
Note:
Stops all RF transmission
Major
Reestablish synchronization
Table 49
IQ over Input
Probable Cause
Severity
Corrective Action
IQ over Input ALM
Note:
Stops RF transmission at port with
alarm
Major
Reset
Table 50
VSWR alarm
Probable Cause
Severity
Corrective Action
VSWR ALM
Note:
Stops RF transmission at port with
alarm
Major
Reset
Table 51
RX out of order
Probable Cause
Severity
Corrective Action
RxGainALM
Note:
Stops RF transmission at port with
alarm
Major
Reset
Maintenance and Trouble Clearing
RU Alarms
138
Release 1.0
·
Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only