6.2
Replace RU Mounted on Pole
This procedure describes how to replace a RU that is mounted on a pole.
Prerequisites:
■
Loctite LB 8012 or equivalent lubricant applied to bolts
■
1/2, 7/16, and 11/16 sockets
■
5/8 in. wrench
■
Torque wrench
■
Philips screw driver
■
Power tools (optional)
■
Metric and SAE toolkit
Caution:
All power and cabling must be disconnected from the RU
before starting this procedure.
Attention:
Toute l'alimentation et le câblage doivent être
déconnectés de l'EF avant de commencer cette procédure.
Caution:
The RU is heavy. Fujitsu recommends removing the RU on
a two-person team to avoid damage to the unit or injury to the user.
Attention:
Le RU est lourd. Fujitsu recommande de retirer l'EF d'une
équipe de deux personnes pour éviter d'endommager l'appareil ou
des blessures à l'utilisateur.
Step 1
If necessary, attach hoisting equipment to eye bolts on top of the RU.
Step 2
Remove the M10 x 40 bolts from the bottom of the mounting plate.
Maintenance and Trouble Clearing
Replace RU Mounted on Pole
140
Release 1.0
·
Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only