FNC00158
5_R
ev_01
Figure 55
Remove RU from Pole Mount
Step 5
Remove the jam nuts from each of the four 10-inch 3/8 bolts holding the small and large crossmembers together.
Step 6
Disconnect the small crossmembers from the large crossmembers by removing the 10-inch 3/8 bolts.
Note:
Fujitsu recommends removing the pole mount plate on a 2-person team to prevent injury or damage to
the equipment.
✓
This task is complete.
Removal
Detach RU From Pole
159
Release 1.0
·
Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only