32
Technical Manual
D2619-N (RX/TX300 S6)
Connectors and indicators
Features
The LEDs have the following meaning:
LED Indicator
Meaning
A - Identification blue on
server is identified via the ServerView
Operations Manager
blue flashing
local monitor off via AVR
B - CSS
(Customer Self
Service)
off
no error (CSS component)
yellow on
indicates a prefailure (CSS component)
yellow flashing
indicates a failure (CSS component)
C - GEL
(Global Error
LED)
off
no error (non CSS component)
orange on
indicates a prefailure (non CSS
component)
orange flashing indicates a failure of a non CSS
component.
Reasons for a failure may be:
- over temperature measured by one of the
sensors
- sensor is defective
- CPU error
- software detected an error
D - LAN link/
transfer
Indicator and meaning see
.
E - LAN speed
Indicator and meaning see
.
F - PCI card
off
PCI card okay
orange on
PCI card failure
G - CPU
off
CPU okay
orange on
CPU failure
H - memory
off
memory module running
orange on
memory module failure
I - PS CTRL ok
green on
Power supply controller okay
K - PS CTRL
error
orange on
Power supply controller error
L - main power
green on
main power okay
Summary of Contents for D2619-N
Page 6: ...Technical Manual D2619 N RX TX300 S6 ...
Page 8: ...Technical Manual D2619 N RX TX300 S6 Contents ...
Page 10: ...10 Technical Manual D2619 N RX TX300 S6 Notational conventions Introduction ...
Page 38: ...38 Technical Manual D2619 N RX TX300 S6 Settings Features ...
Page 40: ...40 Technical Manual D2619 N RX TX300 S6 Replacing the lithium battery ...