background image

System Board D2671
for RX200 S4 

Technical Manual

Edition December 2007

Summary of Contents for D2671

Page 1: ...System Board D2671 for RX200 S4 Technical Manual Edition December 2007 ...

Page 2: ...a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2007 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to av...

Page 3: ...ronmental protection 11 3 Features 13 3 1 Overview 13 3 2 Main memory 17 3 3 PCI slots 19 3 4 Screen resolution 20 3 5 Temperature system monitoring 20 3 6 Ports and indicators 22 3 6 1 External ports and indicators 25 3 6 2 Internal diagnostic LEDs indicators 29 3 6 3 Settings with jumpers 30 4 Replacing the lithium battery 33 Abbreviations 35 ...

Page 4: ......

Page 5: ...or semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key symbols Quotation marks Indicates names of chap...

Page 6: ......

Page 7: ...f Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packagin...

Page 8: ...mum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm risk of lightning hazard Batteries V CAUTION Incorrect replacement of lithium battery may lead to a risk of explosio...

Page 9: ...t before touching the components The equipment and tools you use must be free of static charges Remove the power plug from the power socket before inserting or removing boards containing ESDs Always hold boards with ESDs by theit edges Do not touch any exposed pins or conductors on a component Use a grounding cable designed for this purpose to connect yourself to the system unit as you install dei...

Page 10: ... when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp ...

Page 11: ...d be switched off until they are needed as well as during long breaks and after completion of work Packaging information Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling consumables Please dispose of batteries in accordance with local regulations In accordance wit...

Page 12: ...rding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu Siemens Computers branch or from our recycling center in Paderborn Fujitsu Siemens Computers Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device must not be disposed of with domestic waste This device is labeled in c...

Page 13: ...Performance processors with 1066 1333 MHz front side bus 266 1333 MHz quadruple transmission rate second level cache 8 MB max clock frequency 3 GHz and more max power draw 120 W Intel Quad Core Xeon Harpertown Harpertown Performance processors with 1066 1333 MHz front side bus 266 1333 MHz quadruple transmission rate second level cache 12 MB max clock frequency 3 GHz and more max power draw 120 W ...

Page 14: ... and Ethernet Controller with PCI Express ISCSI 1 0 iSER Host Bus Adapter HBA RDMA Network Interface Controller RNIC TOE Chimney enabled network accelerator Supports WOL functionality with Magic PacketTM Supports PXE functionality Remote Boot Onboard iRMC S2 Server Management Controller with integrated graphics controller and associated 10 100 service LAN port Flash EPROM for IME firmware BIOS LAN...

Page 15: ...t 2 RJ45 LAN ports 1 service LAN port PCI slots There are three PCI expansion slots on the system board Two PCI Express x8 expansion slots One PCI Express x4 expansion slot low profile half length The Riser card contained in the PCI Riser Kit optionally provides three expansion slots arranged at an angle of 90 instead of the three expansion slots on the system board One standard half length PCI Ex...

Page 16: ...Hardware Design Guide 3 0 WfM 2 0 IPMI V2 0 ACPI 1 0b support LSI SCSI BIOS with IME Integrated Mirroring Enhanced USB keyboard mouse boot possible from CD ROM USB drive LAN PXE and iSCSI console redirection support OEM logo CPU memory disable memory mirroring and memory sparing support Environmental protection Battery in holder Form factor 285 x 455 mm ...

Page 17: ...e Single Device Data Correction SDDC function is supported The 12 slots are divided into 4 channels with 3 slots each Channel 1 FBD 1A FBD 2A and FBD 3A Channel 2 FBD 1B FBD 2B and FBD 3B Channel 3 FBD 1C FBD 2C and FBD 3C Channel 4 FBD 1D FBD 2D and FBD 3D Figure 2 Structure of the main memory in channels and slots 1 DIMM slots channel 1 FBD 1A 3A 3 DIMM slots channel 3 FBD 1C 3C 2 DIMM slots cha...

Page 18: ...Gbyte modules In the case of a mixed configuration the memory module pairs with the lower capacity should be installed first Install identical modules of the same type manufacturer speed timing and organization per the instructions below When operating in non mirror mode Always use two DIMMs per configuration for a memory upgrade Install the first pair in the FBD 1A and FBD 1B slots Observe the fo...

Page 19: ...on the system board using a Riser card The Riser card provides three expansion slots at an angle of 90 to the system board two slots for PCIe controllers and one slot for a RAID card PCI slot Description 1 PCI Express x8 low profile half length 2 PCI Express x8 standard profile half length 3 PCI Express x4 mechanically x8 low profile half length ...

Page 20: ...g In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The temperature and system monitoring are controlled by the iRMC controller integrated Remote Management Controller The following functions are supported Temperature monitoring Measurement of the processor temperature measurement of the ambient temperature by a temper...

Page 21: ...ge exceeds warning level high or falls below warning level low an entry in the SEL will be generated If the corresponding agents are installed also an alert will be generated System Event Log SEL All monitored events of the system board are signalised via the Global Error LED and recorded in the System Event Log They could be retrieved in the BIOS Setup or via ServerView PRIMERGY Diagnostic LEDs L...

Page 22: ... RX200 S4 Ports and indicators Features 3 6 Ports and indicators Figure 4 Schematic overview of the system board D2671 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 25 27 28 29 30 31 32 33 34 35 36 37 38 39 ...

Page 23: ...T1 PS 2 keyboard port violet 10 U11 Broadcom BCM5708C NetXtreme Gigabit Ethernet Controller 11 FBD 1D 3D Channel 4 DIMM slots 12 FBD 1C 3C Channel 3 DIMM slots 13 CN7 PCI Express x4 expansion slot low profile half length mechanically x8 Intended for an optional SAS RAID card only 14 U12 Intel 5000P chipset north bridge 15 FBD 1B 3B Channel 2 DIMM slots 16 FBD 1A 3A Channel 1 DIMM slots 17 CN1 Fron...

Page 24: ... connector of the backplane board 28 U60 Intel ESB2 T Enterprise South Bridge 2 T chipset 29 S1 System configuration switch 30 CN29 Internal USB cable connector USB 2 0 31 BZ1 Internal buzzer 32 U59 SMSC DME1737 Super I O chipset 33 U77 Firmware hub FWH 34 BT1 System RTC battery 35 JP2 Clear CMOS jumper 36 U50 iRMC chipset 37 CN4 PCI Express x8 expansion slot low profile half length 38 CN8 PCI Exp...

Page 25: ... system board 1 PS 2 keyboard port violet 6 USB ports 2 PS 2 mouse port green 7 Serial port COM 3 GbE LAN port 1 also for iRMC server management function 8 Video port blue 4 ID indicator blue LED 9 GbE LAN port 2 5 Global error CSS LED indicator bicolor LED amber yellow 10 Service LAN port for iRMC server management function 1 2 3 4 5 6 7 8 9 10 ...

Page 26: ...es orange when a critical event has occurred You can obtain details relating to the event in the BIOS setup in the System Event Log or in ServerView The indicator also flashes in standby mode Steady orange signal when a prefailure event has been detected for a non CSS component You can obtain details relating to the event in the System Event Log or in ServerView The indicator is also bright in sta...

Page 27: ...a management interface iRMC S2 and is prepared for operation with RemoteView Optionally LAN port 1 can also be used for iRMC server management Each LAN port has two LEDs which display the speed of the connection and its status Figure 6 LAN indicators of the system board Pos Indicator Description 1 LAN activity standard LAN Steady green signal when a LAN connection exists Remains dark when no LAN c...

Page 28: ...signal when a LAN connection exists Remains dark when no LAN connection exists Flashes green when LAN transfer takes place 4 LAN transfer rate service LAN Steady green signal in the event of a LAN transfer rate of100 Mbps Remains dark in the event of a LAN transfer rate of 10 Mbps Pos Indicator Description ...

Page 29: ...D2671 RX200 S4 Technical Manual 29 Features Ports and indicators 3 6 2 Internal diagnostic LEDs indicators Figure 7 Diagnostic elements on the system board above and fan board below 1 2 3 4 5 ...

Page 30: ...ents when the associated diagnostic LED s go bright 3 6 3 Settings with jumpers Clear CMOS jumper JP2 Figure 8 Position of the jumpers Pos Description 1 DIMM diagnostic LED indicators 2 Processor diagnostic LED indicators 3 PCI diagnostic LED indicators 4 Diagnostic LED button 5 System fan diagnostic LED indicators Pos Description 1 2 Normal not clear CMOS settings default setting 2 3 Clear CMOS s...

Page 31: ...der access to jumper JP2 Clear CMOS Ê Remove jumper JP2 from position 1 2 and insert it in position 2 3 for 20 to 30 seconds Ê Insert jumper JP2 in position 1 2 again Ê Insert all the expansion cards and the PCI Riser card again Ê Close the server s housing cover Ê Connect all the power and connection cables again Ê Switch the server on again Ê During the POST process press F2 in order to enter th...

Page 32: ...ted in bold text is the default setting Switches Function Status Description S1 1 BIOS recovery On Boot block enabled Off Normal boot S1 2 Skip BIOS password query On Password disabled Off Password enabled S1 3 BIOS write protect On BIOS can only be read Off BIOS can both be read and written to S1 4 CMOS clear On Clear CMOS settings and restore system defaults Off Normal CMOS settings ...

Page 33: ...placed with an identical battery or a battery type recommended by the manufacturer CR2450 Do not throw lithium batteries into the trashcan It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 10 Replacing the lithium battery Ê Press the locking spring into direction of ...

Page 34: ......

Page 35: ...isted here are valid for the described system board ACPI Advanced Configuration and Power Managament Interface ASSR Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port CPU Central Processing Unit CRU Customer Replaceable...

Page 36: ... Desktop Management Interface DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD FWH Firmware Hub HPC Hot plug Controller I2 C Inter Integrated Circuit ICE In Circuit Emulation ...

Page 37: ...ation Of PCI IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface iRMC Integrated Remote Management Controller IRQ Interrupt Request LAN Local Area Network LED Light Emitting Diode MCH Memory Controller Hub MPS Multi Processor Specification NMI Non maskable Interrupt NOS Network Operating System ODD Optical Disc Drive ...

Page 38: ...erating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analysis PIO Programmed Input Output PLD Programmable Logic Device PS U Power Supply Unit PWM Puls Wide Modulation PXE Preboot eXecution Environment RAID Redundant Array if Inexpensive Disks RSB Remote Service Board RST ReSeT RTC Real Time Clock ...

Page 39: ...che SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SMB System Management Bus SMM Server Management Mode SMP Symmetrically Multi Processing UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module ...

Page 40: ...40 Technical Manual D2671 RX200 S4 Abbreviations WfM Wired for Management WOL Wake up On LAN ...

Page 41: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...