D2671 (RX200 S4)
Technical Manual
21
Features
Temperature / system monitoring
Sensor monitoring
The removal of, or a fault in, a temperature sensor is detected. Should this
happen all fans monitored by this sensor run at maximum speed, to achieve the
greatest possible protection of the hardware.
Voltage monitoring
When voltage exceeds warning level high or falls below warning level low, an
entry in the SEL will be generated. If the corresponding agents are installed,
also an alert will be generated.
System Event Log (SEL)
All monitored events of the system board are signalised via the Global Error
LED and recorded in the System Event Log. They could be retrieved in the BIOS
Setup or via ServerView.
PRIMERGY Diagnostic LEDs
LEDs on the system board enable to identify defective modules and compo-
nents as well as gaining information on the PDA.