background image

D2870 (RX600 S5) 

Technical Manual

53

Features

Connectors, jumpers and indicators

B

LAN link/transfer 
(system LAN)

Steady green signal when a LAN connection 
exists.

Remains dark when no LAN connection exists.

Flashes green when LAN transfer takes place.

C

LAN link/transfer 
(management 
LAN)

Steady green signal when a LAN connection 
exists.

Remains dark when no LAN connection exists.

Flashes green when LAN transfer takes place.

D

LAN speed 
(management 
LAN)

Steady green signal in the event of a LAN transfer 
rate of 100 Mbit/s.

Remains dark in the event of a LAN transfer rate of 
10 Mbit/s.

Pos.

Function

Description

Summary of Contents for D2870

Page 1: ...Technical Manual English System Board D2870 for PRIMERGY RX600 S5 Technical Manual April 2010 ...

Page 2: ...entation mbH 2010 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 5686 001 fm Copyright 2010 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes ...

Page 3: ...rd assemblies and in the mouse and keyboard are limited life components Use of these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reache...

Page 4: ...otice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain su...

Page 5: ...ual Only for the Japanese market I Although described in this manual some sections do not apply to the Japanese market These options and routines include CSS Customer Self Service USB Flash Module UFM Replacing the lithium battery ...

Page 6: ...Technical Manual D2870 RX600 S5 cognitas Gesellschft für Technik Dokumentation mbH 2010 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 5686 001 fm ...

Page 7: ...ry 22 3 2 1 Fitting rules 24 3 2 2 Memory configuration modes 25 3 2 3 Memory board configuration table 38 3 3 PCIe slots 40 3 4 Screen resolutions 42 3 5 Temperature and system monitoring 42 3 6 Connectors jumpers and indicators 44 3 6 1 Onboard connectors 44 3 6 2 Onboard jumpers 46 3 6 3 Onboard indicators 48 3 6 4 External connectors and indicators 50 3 6 5 Connectors and indicators on the I O...

Page 8: ...Technical Manual D2870 RX600 S5 Contents cognitas Gesellschft für Technik Dokumentation mbH 2010 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 5681 001 fm ...

Page 9: ...format on the ServerView Suite DVD 2 The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server PRIMERGY Abbreviations and Glossary can also be found on the ServerView Suite DVD 2 1 1 Notational conventions The following notational conventions are used in this manual Text in italics indicates commands or menu items Quotation marks indicate names of chapters and terms tha...

Page 10: ...10 Technical Manual D2870 RX600 S5 Notational conventions Introduction cognitas Gesellschft für Technik Dokumentation mbH 2010 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 5682 001 fm ...

Page 11: ...ied staff Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original ...

Page 12: ...bling has to comply with EN 50173 and EN 50174 1 2 standards or ISO IEC 11801 standard respectively The minimum requirement is a Category 5 shielded cable for 10 100 Ethernet or Category 5e for Gigabit Ethernet Never connect or disconnect data transmission lines during a thunderstorm risk of lightning hazard Batteries V CAUTION Incorrect replacement of batteries may lead to a risk of explosion The...

Page 13: ...ou must always discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always hold components with ESDs at the edges or at the points marked green touch points Do not touch any connectors or cond...

Page 14: ...d in straight without damaging components or conductors on the board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp objects screw drivers for leverage Do not damage or modify internal cables or devices Doing so may ...

Page 15: ...ttp primeserver fujitsu com primergy concept for the Japanese market Energy saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for tra...

Page 16: ...ase handle returns recycling and disposal in accordance with local regulations Details regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 333 18010 Th...

Page 17: ...GB 8 GB and 16 GB capacity Up to 1024 GB memory with availability of 16 GB memory modules Minimum 4 GB 2 memory modules Maximum 32 Gbit s band width DDR3 Hardware memory scrubbing Single Device Data Correction SDDC function Chipkill Memory mirroring function Optional hot spare memory function Chipset devices on the system board Intel E7500 chipset 2x Intel Memory Controller Hub MCH Intel Southbrid...

Page 18: ... slots x4 1x PCI Express 1 0 x1 dedicated for I O riser board 1x PCI Express 2 0 x8 dedicated for SAS controller card Server management controller iRMC S2 on I O riser The following features are integrated into iRMC S2 Server class Super I O SIO Remote KVMS Baseboard Management Controller BMC including the following functionality 250MHz 32 bit ARM9 processor IPMI 2 0 6x I2 C SMBus Two 10 100 Ether...

Page 19: ... 1000BASE T 802 3 802 3u and 802 3ab applications Serializer Deserializer SerDes to support 1000BASE SX LX optical fiber and gigabit backplane applications SGMII for external PHY or SFP module Management of MAC and PHY Ethernet layer functions Management of PCI Express packet traffic across its transaction link and physical logical layers External SPI 4 wire serial interface to Flash EEPROM device...

Page 20: ...th up to two USB Flash Modules UFM The module can be used as optional memory for software e g VMware or as a software dongle Trusted Platform Module option The system board can be equipped with a Trusted Platform Module TPM by the manufacturer or by an add on kit This module enables programs from third party manufacturers to store key information e g drive encryption using Windows Bitlocker Drive ...

Page 21: ...S5 Technical Manual 21 Features Overview If a failure occurs please inform your service about the TPM activation before it takes any action and be prepared to provide them with your backup copies of the TPM content ...

Page 22: ...z Thus the system board supports a maximum memory configuration of 1024 GB ECC with memory scrubbing and the single device data correction SDDC function are standard There is no support for non ECC DIMMs Although there is an assignment between memory boards and CPUs see table on page 41 every CPU can access the memory installed in memory boards of all other CPUs The following figure shows the DIMM...

Page 23: ...ory buffers on board so called BOBs Each BOB controls two memory channels e g A B or C D For performance reasons two channels of different BOBs are used in parallel to access the DIMMs The DIMMS that are locked together this way as pairs are called lockstep pairs FNPSZ NPEVMFT T FNPSZ NPEVMFT T FNPSZ DPOUSM CPY FNPSZ DPOUSM CPY 0 PDLTUFQ QBJS PDLTUFQ QBJS PDLTUFQ QBJS PDLTUFQ QBJS FN PSZ CPBSE FN ...

Page 24: ...tem is two DIMMs Memory boards must be fitted with DIMMs in lockstep pairs see figure 3 on page 23 Both DIMMs of a pair must have identical values I This is a general rule Therefore memory boards must be fitted with DIMMs as follows 1 Start with DIMM slots 1B and 1D minimum per memory riser board 2 Now fill DIMM slots 1A and 1C 3 Continue with DIMM slots 2B and 2D 4 Finally fill DIMM slots 2A and ...

Page 25: ... See the D2870 BIOS Setup Utility for PRIMERGY RX600 S5 manual for detailed information Spare mode In spare mode one pair of DIMMs will be spare for the other pairs The spare DIMMs must have the same capacity or higher than the other DIMMs DIMM sparing only relates to BOBs There is no sparing over memory boards or CPUs Figure 5 Absolute minimum configuration in Spare Mode for 2 CPUs and 2 memory b...

Page 26: ...For a performance optimized configuration 4 more DIMMs are necessary They have to be added into the second memory board must be installed in slot 5 Figure 6 Performance optimized configuration for 2 CPUs and 2 memory boards For one upgrade step 4 DIMMs have to be added see next page FNPSZ T CPY 4MPU 0 0 CPY CPY 4MPU 0 0 CPY 4QBSF T 4QBSF T FN PSZ CPBSE 16 16 16 NJO DPOGJH TQBSF FNQUZ ...

Page 27: ...tep again 4 DIMMs have to be added Figure 8 Second maximum upgrade in Spare Mode for 2 CPUs and 2 memory boards FNPSZ T CPY 4MPU 0 0 CPY CPY 4MPU 0 0 CPY 4QBSF T 4QBSF T FNQUZ FN PSZ CPBSE 16 16 16 NJO DPOGJH TU BEEJUJPO TQBSF FNPSZ T CPY 4MPU 0 0 CPY CPY 4MPU 0 0 CPY 4QBSF T 4QBSF T FN PSZ CPBSE 16 16 16 NJO DPOGJH TU BEEJUJPO OE BEEJUJPO TQBSF ...

Page 28: ...s The data are distributed over the Mboxes of each CPU see figure 9 on page 29 Therefore this type is called Intra Socket Interleaving 4 way interleaving mode also called Inter Socket Interleaving This type requires 2 memory boards per CPU and is possible with 2 or 4 CPUs The data are distributed over the Mboxes of two CPUs see figure 10 on page 30 Therefore this type is called Inter Socket Interl...

Page 29: ...have to be added Figure 9 Upgrade configuration for 2 CPUs and 2 memory boards I The same upgrade rules have to be applied for 2 CPUs and 4 memory boards for 3 CPUs and 6 memory boards and for 4 CPUs and 8 memory boards 16 16 16 FNPSZ T CPY 4MPU 0 0 CPY 4MPU 0 0 CPY CPY FNPSZ CPBSE OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO BUB BSF EJTUSJCVUFE PWFS UIF UXP CPYFT PG 16 ...

Page 30: ...nter Socket with 2 CPUs and 4 memory boards For one upgrade step minimum 8 DIMMs one color have to be added Figure 10 Upgrade configuration for 2 CPUs and 4 memory boards I The same upgrade rules have to be applied for configurations with 4 CPUs 16 16 FNPSZ T CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO FN PSZ CPBSE 16 BUB BSF EJTUSJCVUFE PWFS ...

Page 31: ...IMMs one color have to be added Figure 11 Upgrade configuration for 4 CPUs and 8 memory boards I This mode is only possible with 4 CPUs FN PSZ CPBSE 16 FNPSZ T BUB BSF EJTUSJCVUFE PWFS FJHIU CPYFT OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO 16 16 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 16 16 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 ...

Page 32: ...ory will be mirrored from one Mbox to the other Mbox within the same CPU see figure 12 on page 33 Intrasocket Mirroring is possible for all CPU configurations 2 3 or 4 I This mode requires 2 memory boards per CPU 2 4 6 or 8 total All DIMMS must be identical same capacity and technology Intersocket Mirroring Memory will be mirrored from one Mbox to an Mbox on another CPU home agent to mirror agent ...

Page 33: ...2 Memory Boards For one upgrade step minimum 4 DIMMs one color have to be added Figure 12 Upgrade configuration for 2 CPUs and 2 memory boards 16 16 16 FNPSZ T CPY 4MPU 0 0 CPY 4MPU 0 0 CPY CPY FNPSZ CPBSE OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO BUB BSF NJSSPSFE GSPN CPY UP CPY PO TBNF 16 ...

Page 34: ... Boards For one upgrade step minimum 8 DIMMs one color have to be added Figure 13 Upgrade configuration for 2 CPUs and 4 memory boards I The same upgrade rules have to be applied for configurations with 3 or 4 CPUs 16 16 FNPSZ T CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 CPY 4MPU 0 0 OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO FN PSZ CPBSE 16 BUB BSF NJSSPSFE GSPN CPY UP CPY PO TBNF 16 BUB BSF NJSS...

Page 35: ...pgrade step minimum 16 DIMMs one color have to be added Figure 14 Upgrade configuration for 4 CPUs and 8 memory boards 16 16 FNPSZ T OE BEEJUJPO NJO DPOGJH SE BEEJUJPO TU BEEJUJPO FN PSZ CPBSE 16 16 16 BUB BSF NJSSPSFE GSPN POF CPY UP TBNF CPY PO PUIFS 16 BUB BSF NJSSPSFE GSPN POF CPY UP TBNF CPY PO PUIFS 16 JSSPS HFOU ...

Page 36: ...s space in the other Mbox of the same CPU Hemisphere mode is possible with 2 3 or 4 CPUs I All DIMMS must be identical same capacity and technology A memory board must have a capacity of 4 8 16 32 64 or 128 GB The configuration of the memory boards per CPU must be the same Hemisphere Mode with 2 CPUs and 2 Memory Boards Figure 15 Minimum configuration for 2 CPUs and 2 memory boards 16 FNPSZ T 16 C...

Page 37: ...t be the same For the second upgrade step 16 DIMMs green color must be added because both channels ch 1 ch 2 must be configured the same way Since channel 1 is equipped with 16 DIMMs after the first upgrade step channel 2 also has to be equipped with 16 DIMMs I The same upgrade rules have to be applied for configurations with 3 and 4 CPUs 16 16 FNPSZ T FN PSZ CPBSE 16 OE BEEJUJPO TU BEEJUJPO NJO D...

Page 38: ...elow 2 way configuration 3 way configuration Memory Mode CPU 1 CPU 2 CPU 3 CPU 4 No of Mem boards None Lock step Spare Inter leaving 2 way Mirror Intra socket Memory Board Slot No 1 2 3 4 5 6 7 8 2 X X 1st 2nd 3 X X 1st 3rd 2nd 4 X X 1st 3rd 2nd 4th 4 X X 1st 2nd 3rd 4th Memory Mode CPU 1 CPU 2 CPU 3 CPU 4 No of Mem boards None Lock step Spare Inter leaving 2 way Mirror Intra socket Memory Board S...

Page 39: ...ne Lock step Spare Inter leaving 2 way Mirror Intra socket Memory Board Slot No 1 2 3 4 5 6 7 8 2 X X 1st 2nd 3 X X 1st 3rd 2nd 4 X X 1st 3rd 2nd 4th 4 X X 1st 2nd 3rd 4th 5 X X 1st 5th 3rd 2nd 4th 6 X X 1st 5th 3rd 2nd 6th 4th 6 X X 1st 2nd 5th 6th 3rd 4th 7 X X 1st 5th 3rd 7th 2nd 6th 4th 8 X X X X 1st 2nd 5th 6th 3rd 4th 7th 8th ...

Page 40: ...L OBJ_DOKU 5684 001 fm 3 3 PCIe slots Figure 17 PCIe slots on system board D2870 Pos PCIe slot Description Hot plug A Slot 10 PCI Express 1 0 x4 1 2 length x8 connector no B Slot 9 PCI Express 1 0 x4 1 2 length x8 connector no C Slot 8 PCI Express 2 0 x4 3 4 length x8 connector no D Slot 7 PCI Express 2 0 x8 3 4 length x8 connector yes K L F G H I J A B C D E ...

Page 41: ...lot 5 PCI Express 2 0 x16 3 4 length x16 connector no G Slot 4 PCI Express 2 0 x4 1 2 length x8 connector no H Slot 3 PCI Express 2 0 x4 1 2 length x8 connector no I Slot 2 PCI Express 2 0 x8 3 4 length x8 connector no J Slot 1 PCI Express 2 0 x8 3 4 length x8 connector no K I O riser PCI Express 1 0 x1 PCIe type connector no L SAS ctrl PCI Express 2 0 x8 x8 connector no CPU Mem board PCI slot Rem...

Page 42: ...rature and system monitoring is controlled by an onboard controller that supports the following functions Temperature monitoring Measuring of the processor temperature and ambient temperature by way of a temperature sensor Fan monitoring The fans are monitored Fans that are blocked sluggish or no longer available are detected Fan control The fans are regulated according to temperature Maximum spee...

Page 43: ...aximum speed to ensure the highest possible protection of the hardware Power monitoring When the voltage exceeds or falls below the warning levels an alert is issued System Event Log SEL All monitored events of the system board are signalized via the Global Error LED or CSS LED and recorded in the System Event Log They could be retrieved in the BIOS Setup iRMC S2 s Web interface or via the ServerV...

Page 44: ...C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 5684 001 fm 3 6 Connectors jumpers and indicators 3 6 1 Onboard connectors Figure 18 Connectors on system board D2870 Pos Connector Pos Connector A PCIe slots see figure B I O riser slot 1 2 3 4 5 6 7 8 1 2 3 4 1 2 3 4 5 6 7 8 9 10 B C G F M P L M N M O L M H I J G E D 5 4 3 2 1 0 K A ...

Page 45: ...ure G internal USB ports 2x H HDD activity I TPM Trusted Platform Module J internal USB cable conn K Processor sockets see figure L Signal connectors to Front Panel Fan Board M Power connectors to Power Distribution Board N Signal connector to Power Distribution Board O Power connector to Power Distribution Board P Memory board slots see figure Pos Connector Pos Connector ...

Page 46: ...schft für Technik Dokumentation mbH 2010 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 5684 001 fm 3 6 2 Onboard jumpers Figure 19 Position of the jumpers on system board D2870 Pos Jumper A Clear CMOS J5C2 B Password Disable Clear J5C3 C Reserved J5C1 D BIOS Recovery J6D1 D C B A ...

Page 47: ...nd indicators Settings of Jumper Clear CMOS J5C2 Settings of Jumper Password Disable Clear J5C3 Settings of the reserved Jumper J5C1 Settings of Jumper BIOS Recovery J6D1 Clear CMOS Normal Default Disable Clear Protect Default Default setting Recover Normal Default ...

Page 48: ...pp tim_local work PICHOL OBJ_DOKU 5684 001 fm 3 6 3 Onboard indicators Figure 20 Indicators and indicate CSS button on system board D2870 The positions in the figure have the following meaning Pos Indicator A Hot swap status LEDs for PCIe slot 7 B Hot swap status LEDs for PCIe slot 6 C CSS LEDs for PCIe slots 1 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 F G H I A B D E C ...

Page 49: ...e only visible after the cover has been removed If the server has been powered off power plugs must be disconnected it is possible to indicate the faulty component by pressing the indicate CSS button D VRM PWRGD LED E Platform Reset LED F System ID LED G CSS LED for SAS controller card slot H Indicate CSS button I CSS LEDs for CPU 1 4 see figure Pos Indicator ...

Page 50: ...chft für Technik Dokumentation mbH 2010 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 5684 001 fm 3 6 4 External connectors and indicators Figure 21 External connectors and indicators on system board D2870 Pos Indicator A System ID LED B System ID button C 2x USB connector B A C ID ...

Page 51: ...l Gigabit Ethernet controllers system LAN and an ARM9 controller management LAN These LAN controllers support transmission rates of 10 Mbit s 100 Mbit s and 1 Gbit s only system LAN They also support WoL functionality by means of Magic Packet Pos Indicator A 4x LAN connector LED description on page 52 B Global Error LED orange C Serial connector D Video connector VGA E CSS LED yellow F Management ...

Page 52: ... is used as a management interface iRMC S2 and is prepared for operation with the Remote Management Each LAN controller connector has two LEDs that indicate the transfer rate A and the state B of the connection Figure 23 LEDs of the LAN ports on the I O riser board Pos Function Description A LAN speed system LAN Steady yellow signal in the event of a LAN transfer rate of 1 Gbit s Steady green sign...

Page 53: ...s Flashes green when LAN transfer takes place C LAN link transfer management LAN Steady green signal when a LAN connection exists Remains dark when no LAN connection exists Flashes green when LAN transfer takes place D LAN speed management LAN Steady green signal in the event of a LAN transfer rate of 100 Mbit s Remains dark in the event of a LAN transfer rate of 10 Mbit s Pos Function Description...

Page 54: ... Technical Manual D2870 RX600 S5 Connectors jumpers and indicators Features cognitas Gesellschft für Technik Dokumentation mbH 2010 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 5684 001 fm ...

Page 55: ...acturer This information doesn t apply to the Japanese market Do not throw lithium batteries into the trash can They must be disposed of in accordance with local regulations on special waste Make sure you insert the lithium battery the right way round the positive pole must be on the housing side Figure 24 Replacing the lithium battery boards removed for clarity Ê Press the metal clip in the direc...

Page 56: ...56 Technical Manual D2870 RX600 S5 Replacing the lithium battery cognitas Gesellschft für Technik Dokumentation mbH 2010 Pfad C Programme FCT tim_app tim_local work PICHOL OBJ_DOKU 5685 001 fm ...

Reviews: